Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
104-110 NW 5th Avenue, C - FMSF
1 lorida r Site#8 P808216 Master , r :� ; HISTORICAL STRUCTURE FORM Reorder# Slte Electronic Version 1.1.0 Field Date 10/31/2008 File Form Date 11/4/2008 First Site Form Recorded for this Site? NO Fom1NO 200810 FormNo=Field Date(YYYYMM) GENERAL INFORMATION Site Name(address If none) Patrick Building Multiple Listing(DHR only) Other Names Surveyor Project Name west Settlers Historic District Survey# .............................. National Register Category Building(s) LOCATION & IDENTIFICATION Address Street No. Direction Street Name Street Type Direction Suffix 104-110 NW 5 Avenue Cross Streets(nearest/between) N.w. 5 Ave. bet. 1&2 Street City/Town(within 3 miles) Delray Beach In Current City Limits? YES County Palm Beach Tax Parcel#(s) 12-43-46-16-01-019-024 Subdivision Name Town of Linton Block 19 Lot 24,25,26 Ownership Private Individual Name of Public Tract(e.g.,park) Route to(especially if no street address) MAPPING USGS 7.5' Map Name Publication Date >>DELRAY 'BEACH;1962 ';1983 Township: Range: Section: 1/4 section: >> 46s ;43E ;16;17NSP Irregular Section Name: Landgrant UTM:Zone 17 Easting 59173 Northing 292715 Plat or Other Map(map's name,location) DESCRIPTION Style Masonry Vernacular Other Style Exterior Plan Rectangular Other Exterior Plan Number of Stories 1 Structural System(s) >> Concrete block Other Structural System(s) Foundation Type(s) >> slab Other Foundation Types Foundation Material(s) >> Poured Concrete Footing Other Foundation Material(s) Exterior Fabric(s) >> stucco Other Exterior Fabric(s) Roof Type(s) >> Flat Other Roof Type(s) Roof Material(s) >> Built-up, Other Roof Material(s) Roof Secondary Structure(s)(dormers etc) Other Roof Secondary Structure(s) Number of Chimneys Chimney Material Other Chimney Material(s) Chimney Location(s) Page 1 of 3 • , 8P808216 HISTORICAL STRUCTURE FORM DESCRIPTION (continued) Window Descriptions Fixed;glass block Main Entrance Description(stylistic details) Multiple entrances; glass & aluminum commercial doors Porches: #open #closed #incised Location(s) Porch Roof Types(s) Exterior Ornament Stepped parapet Interior Plan Other Interior Plan Condition Good Structure Surroundin a s Commercial:MOSTiy this category Residential: SOME of this category Institutional: Undeveloped: Ancillary Features(Number/type of outbuildings,major landscape features) Archaeological Remains(describe): None If archaeological remains are present,was an Archaeological Site Form completed? Narrative Description(optional) Early commercial structure in the community HISTORY Construction year 1945 Architect(last name first): Builder(last name first): Changes in Locations or Conditions Type of Change Year of Change Date Change Noted Description of Changes >> Altered-not to standards;;;Original commercial windows replaced Structure Use Histor Use Year Use Started Year Use Ended >> Grocery store;1945; Other Structure Uses Various commercial uses Ownership History(especially original owner,dates,profession,etc.) RESEARCH METHODS Research Methods >> Building permits Other research methods Sanborn maps; FMSF records SURVEYOR'S EVALUATION OF SITE Potentially Eligible for a Local Register? Name of Local Register if Eligible West Settlers Historic District Idividually Eligible for National Register? NO Potential Contributor to NR District? NO Area(s)of historical significance >> African American Other Historical Associations Explanation of Evaluation(required) Early commercial structure in the community. Site of a "corner store" since the early 1920s Page 2of3 HISTORICAL STRUCTURE FORM 8PB08216 DOCUMENTATION (Photos, Plans, etc.) Photographic Negatives or Other Collections Not Filed with FMSF.Including Field Notes.Plans.other Important Documents. Document type: Maintaining Organization: File or Accession#: Descriptive Information: RECORDER INFORMATION Recorder Name(Last,First) Rodriguez, Ivan Recorder Address/Phone 2199 Ponce de Leon Blvd. Coral Gables, FL 305-444-7799 Recorder Affiliation Other Other Affiliation R.J. Heisenbottle Arcitects, P.A. Is a Text-Only Supplement File Attached(Surveyor Only)? ****** MASTER SITE FILE USE ONLY****** Cultural Resource Type: SHPO's Evaluation of Resource Electronic Form Used: Date Form Type Code: Form Quality Ranking: Form Status Code: Supplement Information Status: FMSF Staffer: Supplement File Status: Computer Entry Date: Form Comments: REQUIRED (1) USGS 7.5" MAP WITH STRUCTURE PINPOINTED IN RED PAPER (2) LARGE SCALE STREET OR PLAT MAP ATTACHMENTS (3) PHOTO OF MAIN FACADE, B&W, AT LEAST 3"X5" Page 3 of 3 IIPF . 1 . IR , . •••• A.;.,.. A / ,. _-:.....,,.. . 46 11 11 4 . -1 '.• .. , I , .. 4 it 411114. ; . liEpil II . ., . . ,•I 1 i , 1 i. k , •r6 I , 4 lt:k 1 1111 1111 _111' k .:, t:_._, ' 4111k J i I . . ...... . . . I g-711 . . • ..., ... f 0 11114' .‘v . - -.. -.11 ... III 11113 . . . . , ... , .: -t-„:, :.,. '''' _,, . . i . .5 ..._ s rIii. t ..� A 1w =f '' -.I lo ' . I HUH . E._. - ...1K. _ _________ . : r 1[;::-_-4 _ .4 . __ r. ir_ .___t p`. r 1 I �� _r_i_,......„ ..t L — . . .. ._. ...,....__ ......?,.. ______ ___.........._....._t_..,... 7-- 1 .:� 4.• 1 •••. { , • ' ic- 1. 1 , - • P 4liiii ' ' tut►. r. i i' -----------„ Ar--,_ 4, .. , 4. ... ___ , . -- �- Patrick Building 8PB8216 104 tO 110 NW 5th Avenue Const. Date 1945 8/96 Camera facing west Roll 2 Negative it- b • >.. • Page 1 HISTORICAL STRUCTURE FORM Site 8PB8216 X original FLORIDA MASTER SITE FILE update Version 1.1: 3/89 Recorder# SITE NAME Patrick Building HISTORIC CONTEXTS W War 2&Aftermath NAT. REGISTER CATEGORY Building OTHER NAMES OR MSF NOS None COUNTY Palm Beach OWNERSHIP TYPE Private-individual PROJECT NAME West Settlers Historic District Survey DHR NO LOCATION (Attach copy of USGS map, sketch-map of immediate area) ADDRESS 104-106-108& 110 NW 5th Avenue CITY Delray Beach VICINITY OF/ROUTE TO On the NW corner of NW 5th Ave& NW 1st Street SUBDIVISION Town of Linton BLOCK NO 19 LOT NO 24,25&26 PLAT OR OTHER MAP TOWNSHIP 46 RANGE 43 SECTION 17 1/4 1/4-1/4 • IRREGULAR SEC? y X n LAND GRANT USGS 7.5' MAP Delray Beach 1962 PR 1973 UTM: ZONE EASTING NORTHING COORDINATES: LATITUDE 26 D 27 M 30 S LONGITUDE 80 D 05 M 0 S HISTORY ARCHITECT: F M L Unknown BUILDER: F M L Unknown CONST DATE 1945 CIRCA RESTORATION DATE(S): MODIFICATION DATE(S): 1962 MOVE: DATE ORIG LOCATION ORIGINAL USE(S) Grocery store/Drug store and commercial unspecified PRESENT USE(S) Grocery store/commercial unspecified vacant DESCRIPTION STYLE Masonry vernacular PLAN: EXTERIOR Irregular INTERIOR NO.: STORIES 1 OUTBLDGS PORCHES DORMERS STRUCTURAL SYSTEM(S) Concrete block EXTERIOR FABRIC(S) Stucco/wood/brick FOUNDATION: TYPE Slab MATLS Poured concrete INFILL PORCHES None ROOF: TYPE Flat SURFACING Built-up SECONDARY STRUCS. None CHIMNEY: NO MTLS LOCNS WINDOWS Fixed/glass block EXTERIOR ORNAMENT Brick on parapet CONDITION Deteriorated SURROUNDINGS Commercial NARRATIVE(general, interior, landscape, context;3 lines only) No architectural significance. The only character defining element remaining is the decorative stepped brick parapet on the east facade. Best known as the neighborhood's'corner-stores", a typical commercial pocket in a residential neighborhood in the early African-American community. ARCHAEOLOGICAL REMAINS AT THE SITE FMSF ARCHAEOLOGICAL FORM COMPLETED? y X n (If y, attach) ARIFACTS OR OTHER REMAINS None observed AH6E03102-89 Fla.Master Site File, Division of Historical Resources,The Capital,Tallahassee, FL 32399-0250/904-487-2333 Page 2 FMSF HISTORICAL STRUCTURE FORM Site 8PB8216 RECORDER'S EVALUATION OF SITE AREAS OF SIGNIFICANCES African-American/architecture-commercial vernacular. ELIGIBLE FOR NAT. REGISTER? y X n likely, need info insf inf SIGNIF.AS PART OF DISTRICT? y X n likely, need info insf inf SIGNIFICANT AT LOCAL LEVEL? X y n likely, need info insf inf SUMMARY ON SIGNIFICANCE(Limit to three lines provided; see Page 3) The building is divided into 4 commercial spaces and is a good example of the commercial vernacular constructed in the neighborhood following VAV 2. A"corner store" has been located on the site since the early 1920s, the original building was demolished to accommodate the present structure. IDHR USE ONLY DATE LISTED ON NR KEEPER DETERMINATION OF ELIG. (DATE): -YES -NO SHPO EVALUATION OF ELIGIBILITY (DATE): -YES -NO LOCAL DETERMINATION OF ELIG. (DATE): -YES -NO OFFICE RECORDER INFORMATION: NAME F Patricia M S L Cayce DATE: MO 8 YR 96 AFFILIATION City of Delray Beach Planning Department PHOTOGRAPHS (Attach a labeled print bigger than contact size) LOCATION OF NEGATIVES Planning Department, City Hall, Delray Beach NEGATIVE NUMBERS Roll #2 Neg 16 M A P PHOTOGRAPH Street/plat map, not USGS 44/1,24/0 ST Attach a B/W photographic print here with plastic clip. Label the ''• print itself with at least: the FMSF site number (survey number or site name if not avaiiabie), direction and date of photograph. 1l Prints larger than contact size are preferable. t ` tof !%o A/a) /sr Sr H REQUIRED: USGS MAP OR COPY WITH SITE LOCATION MARKED UNITED STATES ' DEPARTMENT OF THE INTERIOR .GEOLOGICAL SURVEY WCST PALM•OE.SCH„MI. r rvt. W TH • 07 30,a MI.TO ru.p 02 188t?yE 1 R.42E. e89 R.43 E. • I119p '91 5•: t92 I t93 HAKE WORTHI A a 94 a Mr. O.uM w''Ooc, maiim •L.31 ..,.4 ....) . .... .- 1WY.- l••t,,,h-'r7�/�. _;. I.1.:_ ..I. .._:.-+.�7. I T4os _..._.. -Y i. ,. T �- %/l�l�a p I •- •,� - ^{. • -t �. ,•,--'1,ia rile , 1i i h 'T• _ ; ! F., • �r ;f '.__...- ' ( ( f''Toila•• f i�'1�t''• i %Ii fi1 i i sw t[�2m•filer �f 1 i.-----------•---- ;1: .. .J: 21111 1 ., 44 i 3 2 �••r, vc.+ 1 T''••--4•'r., ( ..� ...-.�,._..v:..�.r.._............,.. .......„i:•'.m�.rr... '..;v.•.' 1n1' •l• "Wi•'` I. / • ib v� Ni 'I-rr/'-1 i•,As' (, %i F 4. �«3: l �r �' • . t..� + .1 ('1 /.I �'P '1c'f5r4 I� y _ —1 • i J'• • �� - II' • '. !^�f,t'. ',1 ••a• •.:�r Court hC�u.O, ' / • 1 t w,;'•. (� . k.. _ t 1 I 1 + ll :1. a t 6 11 .H, i •• •rfvol t. Gul ..- ' .-.. .` _ _ �''. _• , , Theater // _4.2 _ 47 II :O f • i Q I.1 I • • 1 . r• 42 -- w. ) ma,• r 1 .. • C • I 1 ••j.'• 1 = L lTN srj.. we • ,_ ••1 I �• f 1 .LI al ' + .' !I. / ••. "� •1' \ • '.ja�'�1r I, ® �I� �) N j p;4♦ • • _t�'rr• l .. _ 1 ' ''"'' ';,•• 1�I. ; �t�Y, I,ll y• '{�`1'' : 1 �i ,I�JI.I� I \ �.i I I' 1 ter. • 1 • •_Delray Gas �' a p • i .. II ,4C`• nl,`�/�I� /•.L 'M 1 ! t,, .., ].2..T_. ...,,%Y! J i i• I i •I lFa i , 1—. 1 ..r. ,„, i-r . r 1 : :..— ._ ./,:�:., . ' r ' : d r '!: yr N �f y� �t •� �i , ; C 1 26 c.. ' 1( i i I s I T/j��� III - 1 / r '•"•% a ;i•• e V 3 I /��®I� �t j e- C, I 'r '•I • , 1, 1 i*.;'• i I •I•lj` " l 'NV; ;ti,EL} 4 i b •••.I. / , 1 . `... ayl o , I IffumwLw1 '1' $kore,'• .� �/.11 1••�, y� _ 1 4. qn1IIP245 Rim 7,' 4J- •'y .. I3L1 _ .. ... .:...1•• ���Ell ��I�I® .Ephr 1 1 -_... , Cy. o• '+� �- _ Y �® fir, I �i 1 a /6 • FlanPwloc�} kingsland .0'.��I _u.t ..jl o ...'M I .i .4.•I D •. �,�I ,�J�� I I�� rll�� mmil,i e�. I / 1! v .'II, t • • • •. • • . : 'i:: 1 , . D .t i�'�.�,�Id�l.��li , �.f ► 11 rQ/c/ 8/}/Io/eV v 14 o d�rr •1 18 1, • b I .. 1 r'13 .....r„i t %��1Pr'1��•oI.l 1�®; Park�,��� i��t.•• : st54.... .r r; \�/./�) .Srn/i9 Highland Park : . • . "'„,„ "�' Treater Park • :•,.5 ,A,rJ .• 'C R •�- s •;R In •, ••• V' .i ' Radio Towtrso' �"!�/J D ,y• 1•. rp�l.t��,1111"1,';1/117,1 '•N 1• • 1 Ja -^' ) ,-....�..,..,.,•••'1 Sher. rack 4 l; .� ` •EC9 } •�_.:• gilt V. .,2," . 1 75 1• •• . . OCott Course _ p._ _ e ......4. i'i -V X ' :-.• � G - ; ',. - .• . • • ® -x 1 • • it 1 • I �ry �a ~T c: ` ' it 1 CwT' : AIIIin a r'- s !� v)�- .�...- 1 .4 ,... i r e Ridee .l,', .1... o s }itij• I r. H 17 .. ,ti D Ir1Y Blech .`�•'''`�• I Cem '..t•.•F,.�.. ♦ e ue•`'.. • 1 County Club l' t C u ay Club I 1 60_ ! _ �;td .. Acres Ia 13' I �, .... (Wnp _ I. i • q •!i� I'^�1+I Ili'r' (: �... ,.-": }.•t .� •. 1\ SY • •1:1 /� JJJ \clplal'i1... ... ._... .....1!•. lu..,nw ,t y O v ` GEVED "Ai IFD -- SEP1L2005 it If (Ssi)243-7200 Fax; (561)243-72211 P. i ". : ::: 2001 APPLICATION FOR ROOF PERMIT ice ILIaJLL3 Li 14 r [ co of op [ 9 V 42fl 11, Iv CITY RG TWP SEC SURD BLOCK LOT �j BLDG PERMIT NUMBER ROOF PERMIT NUMBER .J /gt' HATE 9 Ito 6os PERMIT FEE S • L V n PLEASE PRINT JOB SITE ADDRESS I - IO LW �5 :44 . PROPERTY OWNER NAME �}C.Y, .&W Rocoek. A54� . PHONE ( ) 3 c - Zoo() PROPERTY OWNER ADDRESS I Oa K)W S • j1VE ROOF CONTRACTOR NAME PA LA W E.0 L F 11J C. PHONE:(____) 3�,a-O91! ROOF CONTRACTOR ADDRESS 103 NV. 416 Si• CITY,_EZc.,IX FAX:( ) ESTIMATED COST $ 31I (check one): NEW or REPLACEMENT TYPE OF ROOF MATERIAL REMOVED f ZAT )-1 NOTE:FOLLOW MANUFACTURER'S INSTRUCTION CONCERNING SHINGLE ALIGNMENT,SEE'EXPOSURE,COURSE LAYOUT,AND FASTENING DETAIL'IN SHINGLE MANUFACTURER'S NOA. ROOF TYPE(CIRCLE): MANUFACTURER: PRODUCT APPROVAL NUMBER: CIO Gil 03 .053/ .oa At F_t3 :12 "PLEASE INDICATE TYPE OF STRUCTURE SINGLE FAMILY iNDUSIRIA14, STORAGE MULTIFAMILY OFFICE _ ASSEMBLY `) GARAGE/CARPORT RETAIL • OTHER k _ r It f C 15- WORKERS COMP # I 51g• 3a3y S e i F t'! - '1+• CONTR.REG. or 1 EXEM (FDiFEIN) # r The forego'',• ; - , ,::.t was wledged before me this I O day of - 20�. by aV' C '2.1 who is personally known to me or who has produced(Type of ID) as identificatign: ttN.Stephen C Rubino Al flj.ConissioA ofN pubes 4 emission DD075905 Siit C r 9L✓•.II; - .q, n} � NOTE: Permit of 7 mays. At dI Fires December 2,2005 pires if work is not started within i -inspection every 186-days or permit expires. Plans mast be on the job bet' inspection will bemade.a Final inspection is required on all permits. Roof/Baidios t A • DATEbe`II-'vJ_ e. l� rer.Iall21/03 ilLta f-/Z-os IeeNW1 Avenue,Delray Beach,FL 33444 • OF Ft . I. 01 !IMAM ADE � \i, C 1 IAMrDADECOUNTY,FLORIDA ri� e ..,1 RO.DADE FLAMER BUILDING ROOFING SYSTEM APPROVAL BUILDING CODE COMPLIANCE OFFICE(BC••) N 850 :n GLER STREET,SUITE 1603 cAtstium Roofing PRODUCT CONTROL DIVISION REVI MIAMI,FLORIDA 33130.1563 I:D „• 'R 4 .37S-2901 FAX(3OJ)37s.290a Sub-Crmte¢orv: SBs/APP,Modified Bitumen NOTICE OF ACCEPTANCE • • * . 'I Dt Wood GAF Material Corporation Clmtsslficalion Premiere 8esrrd aemalUmiaaon#1 • 1361 Alps Road l a� Wayne,NJ 07470 W EX Par TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Scow; TABLE 1 This NOA is being issued under the applicable roles and regulations governing the use of construction materials. ` c du Test Product t The docwmentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Product Dimensions $txclIIaUog • De/grinder, Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having GAF Asphalt Concrete 5,55 gallons ASTM 1?41 Asphalt concrete primer used to promote Jurisdiction(A1iJ). Primer(Matrin*u 307 adhesion of uphalt In built-op roofing. This NOA shall not be valid after the expiration date stated below.The Miami-lade Coon Product Primer) . xP ty OAF Miners!Shield® 60[b.}Sags ASTM D 1863 Graau►ea for surfacing of exposed Division(in Miami Dade County)and/or the AHJ({a trots other titan Waal Dade County)reserve the right to Granules 1001b,bags have this product or material tested for quality assurance proposes.If this product or material fails to perform in asphalt,cold process cement or dll the accepted wanner,the manufacturer will incur the expense of such testing and the AIJJ may immediately emulsion.shall be GAPMineraorfla him revoke,modify,or suspend the use of such product or material within their jurisdiction. BORA reserves the right a licatioaa only.used for flashing to revoke Ibis acceptance,if It is determined by Mimi-Dick County Product Control Division that this product or GAP WeathletCoat49 .5 gallons ASTM 1227 Surface coating for smooth surfaced material fails to meet the requirements of the applicable building code. Emulsion(MatrixT" roofs. This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane Fibered 305 Emulsion) Zone of the Florida Building Code. • GAP Premium bibered 1.5 gallons ASTMD 2824 Pibered&haulntmo coating. DESCRIPTION:GAF Roberold®Modified Bitumen Roof System for Wood Decks. Aluminum Roof Cn1Ung (Maa3ltTa System Pro Aluminum Roof Coating • LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and inhered 301) following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. OAP Jetblack AU Weather 1,5 gallons ASTM D 3019 Refined asphalt blended with a mineral RENEWAL of this NOA shall be considered after a renewal application has been filed and theta has been no Plastic Cement(Matriem ASTM D 3409 stabilizer and fibers. Permits adhesion change in the applicable building code negatively affecting the performance of this product Struadard Wet/Dry Roof to wet and dry surfaces. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change is the GAPGLAS ft7510 39.37"(1 meter) ASTM D 4601 Asphalt Impregnated and coated glass materials,use,anr manufacture of the product or process.Misuse of this NOA as an endorsement of any Wide ant base sheet d/o product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply GAI�GLAS 80 UltitaaT'r 39.37 (1 meter) ASTM D4601 Asphalt Impregnated and coated, with anysection of this NOA shall be cause for termination and removal of NOA. Bare Sheet Wide fiberglass base sheet GAPGLAS Flex Plyni 6 39.37"(1 Dieter) ASTM D 2178 Type VI asphalt impregnated glasa,feit Wide ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by with asphalt coating. •the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,thou it shall GAPGLAS Ply•tc9 39 3'T'(1 meter) ASTM D 2178 Type TV asphalt impregnated glass felt Wide with asphalt coating, ca be done in its entirety. GAPGLASthMine al 39.37"(1 ureter) ASTM D 3909 Asphalt coated,glass fiber mat cap sheet Surfaced Cap Sheer. Wide surfaced with mineral granules. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or Its distributors and shall be available for inspection at the job site at the request of the Building Official. OAFGLAS® 39.37"(1 mete) ASTM D3672 Fiberglass base sheet coated oo both STRATA VENT® Wide ASTM D 4897 sides with asphalt.Surfaced on the This NOA renews NOA#02.4408.10 and consists of pages 1 through 31. Eliminator Perforated . bottom side with mineral granules The submitted documentation was reviewed by Prank Zuloaga,RRC. embedded in issphalde coating with factory perforations. `, ' t b s ett J ri � WV z i.,. 01.(12 .I r'et. NOA No: 03-0501.02 '1-d C 0 r• a *' 11/0G/08 EkpiratioaDate: 11/06/08 . 41 °sI r :e t of 03 1 1.. Approval Date10/23/03 !,r !v ,, t e� " ?, e 1 of 32 �'',�� Page 2 of 32 % Test Product Test Product Product D_lrnensions $neciticatlon Description Product Dimensions Specification Description GAFGLAS®Flashing various Asphalt coated glass fiber mat flashing RUBER0ID TORCH 39.37"(1 meter) ASTM D 6222 Heavy duty,polyester reinforced,asphalt sheet available in three sizes. Granule Wide ASTM D 5147 modified bitumen membrane,granule GAFGLAS® 39.37"(1 meter) ASTM D3672 Fiberglass base sheet coated on both surface. STRATAVENf® Wide ASTM D 4897 sides with asphalt.Surfaced on the RUBEROID TORCH PLUS 39.37"(1 meter) ASTM D 6222 Heavy duty,polyester reinforced,asphalt Eliminator Perforated bottom side with mineral granules Wide $ ASTM D 5147 modified bitumen membrane,granule Mailable • embedded in asphaltic coating. surface RUBEROID®SBS Heat- 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with RUBEROID TORCH FR 39.37"(I meter) ASTM D 6222 Heavy duty,polyester reinforced,coated WeldTM Smooth wide polymer-modified asphalt and smooth Wide ASTM D 5147 with fire retardant asphalt modified surfaced. bitumen membrane,granule surface. RUBEROID®SOS Heat- 1 meter(39.37") ASTM D•6164 Non-Woven Polyester mat coated with RUBEROID 170FR 39.37"(1 meter) ASTM D 6222 Heavy duty,polyester reinforced,coated Welder'Granule wide polymer modified asphalt and surfaced TORCH Wide ASTM D 5147 with fire retardant asphalt modified with mineral granules. bitumen membrane,granule surface. RUBEROIDO SBS Heat- 1 slater(39.37") ASTM D-6164 Non-Woven Polyester mat coated with Ruberoid®20 39.3r(I meter) ASTMM D 6163 D 6163 SOSrein modified as a ph ltbasere mat Weld"'170 FR wide rue retardant polymer modified asphalt Wide and surfaced with mineral granules. • Ruberoid®30 39.37"(1 meter) ASTM D 6163 Non woven fiberglass mat coated with. Wide ASTM D 5147 polymer modified asphalt and surfaced RUBEROID®SBS Heat- 1 meta(39.37") ASTM D-6164 Non-Woven Polyester mat coated with with mineral granules.%tem'PLUS wide polymer modified asphalt and surfaced with mineral granules. Rubesnid®30 FR 39.37"(1 meter) ASTM D 6298 Non woven fiberglass mat coated with Wide ASTM D 5147 fire retardant,polymer modified asphalt RUBHROiD®SBS Heat- 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with and surfaced with mineral granales.r Weld PLUS FR wide fins retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® 39.3T'(1 meter) ASTM D 6163 Woven fiberglass mat coated with RUBEROID Modified Base 39,3T'(1 meter) ASTM D4601;Premium glass fiber reinforced SOS- ULTRACLADO SBS Wide ASTM D 5147 Polymer modified asphalt surfaced with IL UL modified base sheet aluminum.copper or stainless steel foil. Sheet Wide Type RUBEROID®Dual FR 39.3T'(1 meter) ASTM D 6164 Non-woven polyester and fiberglass mat Type 02 BUR Wide . ASTM D 5147 coated with fileretardanl,RUBEROID®Modified 5 gallons ASTM D 3019 Fiber reinforced,tvbherized Adhesive polymer- modified asphalt and surfaced with . Bitumen Adhesive Type III RUBEROID® mineral ggranules.SOS Heat- 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with PA 100(A) One-way valve vent used to relieve built- surrfaced. plastsmic)) Wc1dT"25 wide polymer-modified asphalt and smooth VentStacks(metal and ASTMD 1929 up pressure within the roof system. s 39.37"(1 meter) ASTM D 6222 Non-woven polyester mat coated with ASTM D 635 OAF Veal Stacks are available in metal Ruberoid®Mopor Plulic, Granule Wide ASTM D 5147 withm i eral anasphalt and surfaced GAF Aluminum Emulsion 5 gallons None Mineral colloidal bituminous emulsion with mineral granules. with reflective aluminum flakes RUBEROiD MOP Smooth 1 sq.roll ASTM D 6298 Non-woven polyester mat coated with 87 lbs. ASTM D 5147 polymer-modified asphalt and smooth GAF Aluminum Roof Paint 5 gallons ASTM D2824, Non-fibered•Aluminum pigmented, surfaced. (Matrix'"System Pro Type 1 asphalt redeeming RUBEROID MOP PLUS 39,37"(1 meter) ASTM D 6164 Non-woven polyester mat coated with Aluminum Roof Coating Wide ASTM D 5147 polymer modified asphalt and surfaced Flbered 302) with mineral granules. GAF Built-Up Roofing 100 lb.cartons, ASTM D312, Inter*mopping and surfacing asphalt RUBOROID MOP 170FR 39.37"(1 meter) ASTM D 6164 Non-Woven polyester mat coated with Asphalt bulk Types 1,1>.111 and IV � Wide ASTM D 5147 fire retardant polymer modified asphalt SEgS modified asphalt and surfaced with mineral granules. RUBEROID MOD Asphalt, 60 lb.kegs RUBEROCD MOP FR 39,37"(I meter) ASTM D 6164 Non-Woven polyester mat coated with Asphalt L&Asphalt P 4 roll Fiberglass reinforced shingle Wide ASTM D 5147 fire retardant polymer modified asphalt Shingle-Mate sq' underlayment and surfaced with mineral granules. Underlayment 30 lbs. Y RUBEROID TORCH 39.37"(1 meter) ASTM D 6222 Heavy duty,polyester reinforced.asphalt Tile-Mate Modified Base 1.5 sq.roll ASIM D 5147 SBS ply modisified aspeet halt basee wh a glass fiber sheet and Smooth Wide ASTM D 5147 modified bitumen membrane,smooth Sheet intermat tile underlayment. surface. NOA No:03.950I.02 cA 11'i/ NOA No: 03-0501.02 `�(iir - Expiration Date: 11/06/08 Expiration Date: 11/06/03 Approval Daee:10n3/03 Approval Date:10/23/03 4 Pa e 4 a(32 Page3of32 hip~�� g , Test Product Product Dimensions 6accillcatlon Dessrtptlon APPROVED TNSULA',fIONSt Tile-Mate Modified Cap 1 sq.roll ASTM D 5147 Non-woven polyester mat coated with 103 lbs. polymer modified asphalt and surfaced TABLE 2 with mineral granules tile underlaytnent. Product Name Product Description Manufacturer Tile•Mate Modified Cap 1 sq.roll ASTM D 5147 Non-woven polyester mat coated with (With Current NOA) Plus 102 lbs. polymer modified asphalt and surfaced GAPTEMP Isotherm R.ItA,RN& Polyisocyanurate foam insulation GAP Materials Corp. with mineral granules file underlay ant. Composite,EnergyGuard RA Topcoat®Surface Seal SB 5 gallons Surface coating for smooth surfaced and GAFI'P.MPO Composite A&N Polyisocyanurate foam insulation with GAF Materials Corp. (Matrix 602 SB Coating) mineral surfaced roofs. high density fiberboard or Permslite OAP WeatherCote/0 5 gallons Surface coating for smooth surfaced and partite insulation. MB+(Matrix 715 MB mineral surfaced roofs. (BMCA)OAPTEMPA Fiberboard Fiberboard insulation. OAF Materials Corp. ' Coating) GAFI'EMP*)Pertnalite Perlite insulation board. GAF Materials Corp. Topcoat MB+(Matrix 715 5 gallons Surface coating far smooth surfaced and GAF1 MP GAFCAN Cut pale board GAF Materials Corp. MB Coating) mineral surfaced roofs. T nr WeathetCo t0"(Matrix 5 gallons Surface coating for smooth surfaced and GAFL EMP Pernmalite Recover Polite recover board GAF Materials Corp. 531 WcatheCote@ mineral surfaced roofs. Board Blastonleric Rasping GAFTBMP GAFEDGE'Tapered Tapered partite board GAF Materials Corp. Grade) Edge'Strip Matrix.Low VOC 5 gallons Surface coating for smooth surfaced and mineral surfaced mots. (BMCA)OAFTEMPO Illgh High density wood fiberboard insulation. GAF Materials Corp. Matrix 101 System Pro SBS 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt Density Eberboard Adhesive Adhesive BMCA PnergyOuard,RA Polyisocyatnute foam insulation BMCA (RuberuidOMB)Matrix 5 gallons ASTM D3019 Cold Applied Modified SBBS Asphalt 201 System Pro SBS Adhesive—Flashing Grade. BMCA Composite EnergyGuard, Polylsocynmure/wood fiberboard BMCA Flashing RA composite (Rubcroid9MB)Matrix 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 Select SBS Adhesive Adhesive. PYROX Polylsocyanurate foam insulation Apache Products Co. • (RubcroidOMB)Matrix 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt 202 Select SBS Flashing Adhesive-Flashing'Grade. White Line Polyisocyanwate foam insulation Apache Products Co. Matrix 203 Standard Plastic 5 gallant ASTM D4S86 Standard Plastic Asphalt Roofing AC7'oum I,A&Composites Polyisocyanurate foam insulation • Atlas Energy Products Cement Cement Matrix 213 Gun Grade 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing ISO 95+ Polyisocyanurate foam inaulullon Firestone Building Plastic Cement Cement Caulk Grade. Rndncrs,Inc. Matrix 103 Cold Ad sive 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. ISO 95+Composite Polyisacyantrate/perlite ridged Firestone Building Matrix 303 Select Fibered 5 gallons ASTM D 2824 Fibered aluminum coaling. Insulation Prodncta,Inc. Aluminum Matrix 304 Select Non- 5 gallons ASTM D2824, Non-fibened.Aluminum pigmented, EPS Extruded polystyrene insulation Generic Fibered Type 1 asphalt roof coating, • Wood Fiber Wood filer insulation board • Generic RUBEROIDd9 Modified 5 gallons ASTM D 3019 Fiber reinforced,rubberized Adhesive Bitumen Adhesive Type III High Density Wood Fiberboard Wood fiber insulation board Generic Pelite/Ure hone Composite Periite I urethane composite board Generic insulation Polite Insulation Perlite insulation board generic Dens Deck Water resistant gypsum board G-P Gypsum Corp. ' E'NRGYY•2&13NRO'Y•2 PLUS, Polyisocyanurate foam insulation Johns Manville UltraOard Gold `;t!tr/� NOA No: 03.0501.02 It*, NOA No: 03-0501.02 Expiration Date: 11/06/08 Expiration Date: 11l06I08 j Approval Date:10/23/03 -t.�1- Approval Detc:10/23/03 .•;r�, `. Page %ot�Ia Page 6 of 32 • APPROVED INSULATIONS: APPROVED FASTENERS: TABLE2 TABLE3 Product Name Product Description Manufacturer Fastener Product Product (With Current Manufacturer PlberOlass Roof Insulation Glass fiber/M3neral fiber insulation Johns ManvilleOA) Number Name Description Dimensions (With Currant NOA) Pol is 13, Olympic Fastener#12& Insulation fastener Olympic Manufacturing ISORoc y ocyanurate foam/rockwool Johns Manville #14 • Group,Inc. composite insulation 14. Olympic Fastener ASAP Pre-assembled Insulation Olympic Manufacturing Structodek Wood fiber insulation board Marmite. fastener and plate Group,Inc. 15, Olympic Polypropylene Polypropylene plastic plate 3.25"round Olympic Manufacturing Multi-Mu&FA Polyisocyanurate roof insulation RMax.Inc. Panic Base Board Rockwool issuladon Partek, Group,Inc. Perot Cap Board16, Olympic 0-2 3.5"round galvalume 3.5"round Olympic Manufacturing AZSS steal plate Group,Inc. A.PPROVED FASTENERS: 17. Olympic Standard 3"round galvalume AZ.50 3"round Olympic Manufacturing TABLE 3 steel Plate Group,Inc. 18. Insul-Pbot Fastener Insulation fastener for steel SFS/Stadler Fastener Product Product Manufacturer and wood decks • Number Name Description 1)Imenaions (W M Current NOA) 19. haul-Fax S Plate 3"round gnlvalutne AZSO 3"round SPS/Stadlec 1. GAFTITP.®(Drill-Tic®) Insulation fastener for GAF Materials steel . #I2 Standard Heavy steel,wood&concrete ' • land-Fix P Piste 3'round polyethylene 3"round SIt3/Sladlcr Duty Roofing Fastener decks. stress plate 2. OAFITIB®(Drill-Tee®) PreassembledGAFITTE OAF Materials 21. TtnFaat • Irani. : faateaerforthee! 1beTtvlaastCorp. ASAP metal and al and and wood decks plastic plates. . 22 Thu-Fast Plates 3"round galvalumo AZSS 3"round The Tru-Fast Corp. 3. OAPTTI1®(ThillTec®) Bess sheet fiatnming OAF Materials steelplate Base Sheet Fastener and assembly. ' 23. Tru-Fast Plates Polyethylene plastic plate 3'round The Ttu•Fast Corp. Plato EVIDENCE SUBMITTED: 4. Gslvalume Plates(Drill- Round galvalume stress 3"and 3114" GAF Materials Corp. Tee®Metal) plates. Teat Arenev Teat Identifier Desautton • 5. Polypropylene Plates Round polypropylene 3"and 3'fa" GAF Materials Corp. (DrillTec4 Plastic) stress plates. Factory Mutual Research Corp. Current Insulation PMRC 1996 01.01.96 6, Dekfust Fastener:#12,#14 Insulation fastener for Construction Fasteners Attachment Requirements &tf IS wood,steel and concrete Inc Factory Mutual Research Corp. FMRC 4470-PA 114 J.I,1B9A8.AM 09,04,97 •,. decks • 7. Dekfast Hex Plate Galvalume hex stress plate. 2 7/8"x Construction Fasteners II 3D4Q2.AM 04.30.97 3 W" Inc. Trinity Engineering Wind Uplift PA 114 4483.04 97.1 06.06.97 8. Dekfast Lock Plate Polypropylene locking 3"x 3 44" Construction Fasteners PRI Asphalt Technologies,Inc. GAF-020-02-01 ASTM D 4977 02.01.02 plate. Inc. IRT of S.Fl. 02.005 TAS 114 01.18.02 9. #12 Roofgrip Fasteners Insulation fastener for ITW Buildex Corp, IRT of S.FL 02-01'4 TAS 114 03.22.02 wood and steel. a 10. Metal Plate Galvalunre stress plate. 3"round ITW Buildex Corp. 3"square 11. Gearlok Plastic Plate Polypropylene round plate 3.2" 1TW Buildex Corp. 12. Glasfast Fastener, Insulation fastener Johns Manville assembly with recessed plastic plate ��,or sI_ NOA No: ll3 US01.02 ��We/ - I3cphxHou Data 11106/03 NOA No;03 OS01.02 6.� Expiration y��aa►v{ Approval Datt:10/13/03 1w Approval alD:10/13/03 Page 7 of 32 r,rP Page 8 of 32 GAFGLAS Flex PIP.'0,GAFGLAS 075 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a APPROVED ASSEMBLIES sheets spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o.c.in the field. (Maximum Design Pressure-52.5 psf,,See General Limitation#7) Membrane Type Type: SBS GAFGLAS N75 Base Sheet or any of above Anchor sheets attached to deck with Deck Type II: Wood,Insulated Deck Description: 'in"or greater plywood or wood plank IDrili•Tec(GAFTITB)#12 or#14 Screws and 3"Plates,12"o.c.id 4 rows. One System Type A(1): Anchor sheet mechanically fastened,all layers of insulation adhered 'jith row is in the 2"Fide lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. approvedasphalt. (Maximum Design Pressure-60 psf,See General Limitation#7) AU General and System Limitationsshall apply, Any of above Anchor sheets attached to deck approved annuls:dug shank nails One or snore layers of any of the following insulations.Insulation Layer Insulation Fasteners Fastenerand 3"inverted Drill-Tee(GAFf1TB)insulation plates at a fastener spacing of 9" o.c.at the 4"lap staggered in two rows 9"in the field. (Table 3) DensilY/Pts (Maximum Design Pressure-60 psf,See General Limitation#7) ACFoatn-1,ENRGY 2,GAFTEMP®Isotherm R,ENRGY 2 Plus,GAFTEMP Isotherm RA, M De gncP a s, sheets limitation to deck with GAFTEMP Isotherm RN,GAFTEMP Composite,GAFTEMP Composite A,GAFTEMP GAFGLAS S#75 Base Sheet or f any ofaws above 3"Anchor e r attachedoa,in 4 rows. One Composite N,ISORoc,BMCA EnergyGtsard,BMCA EnergyGuard Campeche,EnergeeGard 1SO, row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c. Minimum thick RA Composite,EnergyGnatd RA N/A N/A in the field of the sheet. Minimum 1" (Maxi/slims Design Pressure-75 psf,See General Limitation#7) Wood Fiber,GAFTEMP®Fiberboard,BCMA High Density Wood Fiber,GAFTEMP®Rlgh Buse Sheet: (Optional)Install one ply of GAPGLAS®#7s,GAPOLAS#80 ULTIMATM Base Density Wood Fiber,GAFTEhfP Recover Board Sheet,GAFGLAS®PLY 4®,GAPGLAS Flex Plyn,6,GAFGLAS Minimum 34"thick N/A N/A STRATAVENT°Eliminator Perforated(laid dry),RUBEROID Modified Base Sheet,RUBEROID MOP Smooth,RUBEROID®20,RUBEROID SOS Heat. Paroc,Perlte,GA1rFEMP®'Perecalltn N/A t UA Weld'"Smooth or RUBEROID SBS Heat-Weld 2$directly over the top layer of Minimum IV thick insulation. Adhere with any approved mopping asphalt applied within the I:VT range and at a rate of 20.40 lbsisq (see General Limitation#4). Minimum FiberglasN/A N/A Ply Sheet: (Optional)One or atom plies GAFGLAS PLY 4®,GAPGLAS Flex Ply 6 sheet, u/ti'thick GAFGLAS#80,RUBEROID MOP Smooth,RUBEROID®20 adhered in a full Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt mopping of approved asphalt applied within the BVT range end at a rate of 20-40 ' within the EVT range and at a rate of 20-40 lbs1100 ft'. Please refer to Roofing Application lbsisq. Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used Membrane: One or more plies of RUBEROID®20,RUBEROID 30,RUBEROID 30 FR only as base layers with a second layer of approved top layer insulation installed as the final RUBEROID MOP Smooth,Ruberoid®Mop 170 PR,RuberoldtD Mop Granule, membrane substrate. Composite insulation panels may be used as a top layer placed with the RUBBROID MOP PLUS,RUBEROID MOP FR,RUBEROID ULTRACLAD®. polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® or RUBEROID Dual FR fully adhered in an approved asphalt at an application Eliminator Perforated laid dry or a layer of GAFTEMP®PERMALITE or wood fiber overlay rate of 25 lb./sq.215%. board an all Isacyanurate applications. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane)Install one of the following: Anchor sheet: GAFGLAS#80 Ultiman'Base Sheet,STRATAVEN'I®Eliminator Perforated 1, Gravel or slag applied at /sq.and 301)IbJsq.respectively in a flood coat Nailable Base Sheet,RUBBROID Modified Base Sheet,RI BEROIT)®20, ave approved asphalt 60tI00 lb. • RUBEROID SBS Heat-Weldrs'Smooth or RUBBROID SBS Heat-Weld 25 base . sheet mechanically fastened to deck as described below; 2. GAFOLAS Mineral Surfaced Cap Sheet in an approved asphalt at an Fastening GAPGLAS®Ply 4®,GAFGLAS Flax Ply 6,GAFGLAS#75 Base Sheet or any application rate of 25 IbJsq.±15%. Options: of above Anchor sheets attached to deck with approved annular ring shank Halls 3. GAP Weathercota® MB+(Matrix 715 MB Coating), Applied at l to 1.5 t and tin caps as a fastener spacing of 9"o.c.at the lap staggered and in two rows galisq 12"o.c.in the field (Maximum Design Pressure-45 psf,See General Limitation 47) 4. Top Coat®Surface Seal SB(Mauix 602 SB Coating),Applied at i to 1.5 galJaq GAFGLAS®Ply 4®,GAFGLAS Plea Plyna 6,GAFGLAS#75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Tec(GAFTTTB)#12 cr#14 Maximum Design Pressure: See Fastening above. Screws and 3"Plates,12"o.c.in 3 rows. One tow is in the 2"side lap. The other rows arc equally spaced approximately 12"o.c.in the field of the sheet. (Maximum Design Pressure-45 psf,See General Limitation#7) ,s t r .1,r rays NOA No: 03.0501.02 •, NOA Na: 03.0501.02 • 14lratlon Dote: 11i06/08 -`.� "'+ Expiration Date: 1 U06/08 Approval Date:10/23/03 � o Approval Date:10R3/03 (' r Page 9 of 32 'CrS' Page 10 of 32 4i iv, • Membrane Type: APP/SBS Heat Weld GAFGLAS Flex PIyT'"6,OAPOLAS tt75 Base Sheet or any of above Anchor - sheets attached to deck with approved annular ringshank nails and tin caps at a Deck Type 11: Wood,Insulated PP p Deck Deacrl Ilan: " fastener spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o.c.in the P /sa"or greater plywood or wood plank field. (Maximum Design Pressure-52.5 psf,See General Ltmi4uian#7) System Type A(1): Anchor sheet mechanically(attested,all layers of insulation adhered with GAFOLAS#75 Base Sheet or any of above Anchor shoats attached to deck with approved asphalt. Drill-Tee(GAFfITB)#12 or#14 Screws and 3"Plates,12"o.c.in 4 rows. One MI Gwent and System Limitations shall apply row is in the 2"side lap.The other rows are equally spaced approximately 9"o.c. One or momlayers of any of the following insulations.• in the field of the sheet. TnsuleUon Layer , Insulation Fasteners Fastener (M ++rrun Design Pressure-60 psf,See General Limitation#7) (Table 3) Density/re Any of above Anchor sheets attached to deck approved annular ring shank nails ACFeam-1,ENRGY 2,GAF-TEMPO isotherm R,ENRGY 2 Plus,GAFTEMP Isotherm RA, and 3"inverted Drill-Tee(GAF ITB)insulation plates at a fastener spacing of 9" , GAFTEMP Isotherm RN,GAFTEMP Composite,GAFTEMP Composite A,GAFTEMP • o.c.at the 4"lap staggered in two rows 9"in the field. Composite N,ISORoc,GAFTEMP®Tapered,BMCA EttergyGuard,BMCA EnergyGuard (Maxdnrrun Design Pressure-60 psf,See General limitation#7) Composite,EoergyGtuts•d RA,EnetgyGuard RA Compodto GAFOLAS#75 Base Sheet or any of above Anchor sheetsattached to deck with Drill-Tec(GAFTI'fE)012 or 014 Screws and 3"Plates,8"o.c.in 4 rows. One Minimum I"thick WA N/A row is in the 2"side lap. The other rows era equallyspaced approximately 9"o.c. Wood Fiber,GAFTEMP®Fiberboard,High Density Wood Fiber,GAFTEMP®High Density in the field of the sheet. Wood Fiber,GAFTEMP RocoverBoard (kfaxknum Design Pressure-7S psf,See General Limitation 41) Minimum Si"thick N/A N/A Base Sheet; Install one ply of GAFOLAS®#75,GAFOLAS#80 ULTIMATu Base Sheet. GAFGLAS®PLY 444 GAFGLAS Flex Piync 6,GAFOLAS STRATAVEND' Panic,Pedlte,GANTEbtP®Perrrtallte Eliminator Perforated(laid dry),RUBEROID Modified Base Sheer,RUBEROID Minimum 14"thick N/A N/A MOP Smooth,RUBBROA)®20,RUBEROID SBS Heat-WeldT"Smooth or Merest; RUBEROID SBS Heat-Weld 25 directly over the top layer of insulation Adhere Minimum''I "thick N/A N/A with any approved mopping asphalt applied within the BVT range and at a rate of Note: All insulation shall be adhered to the anchor sheet In full mopping of approved butasphalt (Option l sq(see GeneralLimitation#4). Pp L PP Ply Sheet: (Optional except over RUBEROID Modified Base Sheet,RUHFROID MOP within the EVT range and at a rate of 20-401be/100 ft'. Please refer to Roofing Application Smooth,RUBEROID®20,RUBEROID SBS Hut-Weld'Smooth or Standard RAS 117 for Insulation attachment. Ic uladoa listed as base layer only shall be used only RUBEROID SBS Heat-Weld) One or more plies GAFGLAS PLY 41), . as base layer.with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panda may be used as a top layer placed with the mAPGIA5®PLY 60 Ply t GAFGLAS FlexPly d sheet adhered and at a a(till mopping of approved aspbwlt applied within the EVT range and at a rate of 20-40 polyisocyaaarato aide facing down, GAF requires either a ply of GAFGLAS STRATAVENT® lbsisq.or Ruberoid Torch Smooth torch applied according to manufacturer's Ellmluator perforated laid dry or a layer of GAFTBMP®PERMALITE of wood fiber overlay application Instructions. board on all lsomyanurate applications. Membrane: One ply of Ruberoid®Torch Smooth,Ruberoid®Torch Granule,Ruberoid® Anchor sheet: GAFGLAS#80 UltimaTT'Base Sheet,STRATAVENT®Eiminator Performed Torch Pius Granule or Ruberoid®Torch PR torch applied according to Mailable,RUBEROID Modified Base Sheet,RUBEROIDeD 20,RUBEROID SBS manufacturer's application instructions. Heat-Welds"Smooth or RUBEROID SBS Heat-Weld 25 base sheet mechanically Or fastened to dock as described below; One or more plies of RUBEROID®SBS Feat-WeldT"PLUS.RUBEROID®SBS Fastening GAFGLAS®Ply 4®,GAFGLAS Flex PIysu 6,GAFGLAS Y75 Base Sheet or any • Heat-Weldn7e PLUS FR,RUBEROID®SBS Heat-Weld"(170 FR,RUBEROID® Options: of above Anchor sheets attached to deck with approved annular ring shank nails SBS Heat-WeddT'4,RUBEROID®SBS Heat-WeddTT'Smooth,RUBEROID® • and tin caps at a fastener spacing of 9"o.e.at the lap staggered and in two rows UltraCladT"SBS and RUBEROID®SBS Heat•We1dT"25 applied according to • 12"o.c.in the field. (Maximum Design Pressure-45 psi,See General manufacturers application instructions. Limitation#7) Surfacing: (Optional)Install one of the following: tan GAFGLAS®Ply 4®,GAPOLAS Flex Ply 6,OAFOLAS#75 Base Sheet or any 1. Gravel or slag applied at 400 lb.sq.and 300 lb./sq,respectively in a flood coat of above Anchor sheets attached to deck with Drill-Tee(OAFIITE)#12 or#14 of approved asphalt at 60 lbisq. Screws and 3"Plates,12"o.c.in 3 rows. One row is in the 2"side lap, The other 2. GAF Premium Fibered Aluminum Roof Coating,at 1.5 gal./sq.or GAF rows aro equally spaced approximately 12"o.c.in the field of the sheet. WeatberCoatm Emulsion at 3 gal/sq. (Torch Smooth applications only) (Maximum Design Pressure-45 psf See General Limitation#7) 3. GAF Weathercote®MB+(Matrix 715 Mil Coating),Applied at 1 to 1.5 gal/sq. ,ttlr,� NOA No:03.0501.02 tItr • A ': NOA No:03-0501.02 ! '? Expiration Date: 11/06/08 -••L µT_ Approval Date:10/23/03 1 1 Expiration Data 11/06/08 "'I Pagel! 5rty`►`, Approval Page 12 of 32 4. Top Coat®Surface Scat SB(Matrix 602 SB Coating),Applied at'I to 1.5 . gal/sq. Membrane Type: SUS Maximum Design Pressure: Sec Fastening Above Dock Type 11: Wood,Insulated Deck Description: to/n"or greater plywood or wood plank System Type B: Optional base sleet laid dry;base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. ' • All General and System Limitations shall apply. ' One or more layers of any of the following insulations. • Base Insulation Layer Insulation Fasteners Fastener (Table 3) Deusity/fts • ACPoam•I,EnergyGuard RA . Minimum 1.3"thick 1,2,6,9,13 or 14 . 1:3 fta ENRGY 2,GAF FEMP Isotherm RN ' Minimum 1.4"thick 1,2.6,9,13,14 a 21 1:3 fta' GAPTEMIND Isotherm R,BMCA EnergyGuard Minimum 1.3"thick 1,2,6,9,13,14 cr 21 1:3 ft' ENRGY 21'lus,GAFTEMP Composite N,BMCA CompoaitcE.aergyGuard Minlnasam 1.5"thine 6.9,18 or 21 1:3 ft2 Pcailtet GAFTEMPm PERMALITE Minimum 44"thick 1,6,9,13ar 21 1:2 fro . Fiberglas Minimum"la," thick 1,2,6,9,12,13,14,18 or 1:2.67 ftr 21 . Wood Fiber,GAFT'EMP®Fiberboard,GAFTEMP High Density Fiberboard . Minimum 1"thick 1,2,6,13,14 or 21 1:2 ft' Note: Base layers of Insulation shall be mechanically attached using the fastener density Dated. The Insulation panels listed are minimum aches and dimensions;if larger panels are used,the mmtber of!uteuer%shall be Increased maintaining the ume fastener density!Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements.Please refer to Rooting Application Standard RAS 117 for insulation attachrunt GAF requires either a ply of GAFGLAS STKATAVENT® ' ElFmbuttor perforated laid dry or a laiyer of GAIzTEMPP PERMr ALITE or wood fiber overlay board on all isocyanurate applications. Top Insulation Layer Insulation Fastener' Fastener ' (Table 3) Density/RI Any of the Insulation listed for Rase Layer,above. High Density Wood Fiber,GAFTEMPS high Density Wood Fiber,GAFTEMP RecoverBoard Minimum Si"thick N/A N/A 'Panic Minimum i"thick • N/A N/A ,t1 t ei� NOA No: 03-0501.02 4;� �t^ NOA No: 03-0501.02 9 Expiration Date: 1ll06/03 _ - Emir:Won Darr: 11/06a08 = :. ►,;.-at Approval Dak:10/l3/03 `,..'�1" Approval Aate:10/23l03 .6r+I`. Page 13 of 32 %;,awes.. Page 14 of 32 Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT Membrane Type: APP/SBS Heat Weld range and at a rate of 20-40 lbs/100 its. Please refer to Rooting Application Standard RAS 117 for Insulation attachment.Composite insulation boards used as a top layer shall be Installed with the Deck Type II: Wood,insulated polylsocyaaurate face down. Base Sheet: (Optional)install one ply of GAFGLAS®#75,GAPGLAS#80 ULTIMO'Base Deck Dercr{ption: it/ri"or greater plywood or wood plank Sheet.GAFGLAS®PLY 40,GAFGLAS®PLY 60,GAFGLAS Flex Ply'6, System Type B: Optional base sheet laid dry;base layer of insulation mechanically fastened, GAFOLAS STRATAVENTe Eliminator Patented(led dry),RUBBROID optional top lager adhered with approved asphalt. Modified Base Sheet,RUBEROID MOP Smooth or RUBPROID®20 directly and System Limitations shall apply. over the top layer of insulatona. Adhere;with any approved mopping asphalt - applied within the EVT range and at a rate of 20.40 lbs/aq; (see General One or more layers of any of the following insulations. Limitation#4). • Base Laudation Layer Insulation Fasteners Fastener (Table 3) Density/ft3 Ply•Sheet: (Optional)One or mom plies GAFGLAS PLY 40,GAFOLAS Flex Ply 6 sheet or • ACifoam4,EnergyGunrd RA • GAFGLAS#80 Ultima adhered in a frill mopping of approved asphalt applied Minimum 1.3"thick 1,2.6,9,13 or 14 1:3 fta within the EVT range and at a rate of 20.40 ibafsq. ENRGY 2,GAFI'EMP Isotherm RN Membrane: One or more plies of RUBEROID®20,RUBEROID 30.RUBEROID 30 FR • MinIawm 1 A"thick 1,2,6,9,13,14 or 21 1:3 ftr• RUBEROID MOP Smooth,Ratiero1d0 Mop 170 FR,Ruberoid®Mop Granule, GAF TEMPO Isotherm R,BMCA EaergyGuard RUBEROID MOP PLUS,RUBBROID MOP FR,RUBBROID Dual FR or Mtnhmnn 13"thick 1,2,6,9,13,14,18 or 21• 1:3$s RUBEROID ULTRACLAD®,fully adhered in an approved uphill at as • application rate of 25 lb/sq.±1596. ENRGY 2 Pens,GAF TEMP Composite N,BMCA Composite Energ7Guard,EnergyGuard RA • e Surfacing: (Optional,required if RUBEROID MOP Smooth or RUBEROID 20 is top Minimum I.5"thick 6,9,18 or 21 1:3 fta membrane)install one of the following: Pulte,CAFFBM1'r9 PERMALITE 1. Gravel or slag applied at 400 lb/sq.and 300 lb/sq.respectively in a flood coat Itftninuttair thick • 1,6,9,13 or 21 1:2 its of approved asphalt at 60 lb/sq. Fiberglas • 2. GAFOLAS Mineral Surfaced Cap Sheet in an approved asphalt at an Minimum u/H" dick1,2,6,9,12,13,14,18 or 1:2.67 As application rate of25lb/sq.±15%. 21 1. GAF Weathercote® MB4(Matrix 715 MB Coating), Applied at 1 to 1.5 • gal/sq. Wood Fiber,GAF ined)Fiberboard,GAP TEMP High Density Fiberboard 4. Top Coat®Surface Seal SB(Matrix 602 SD Coating),Applied at 1 to 1.5 Minimum 1"thick 1,2,6,13.14 Or 21 1:2 ftx gal/sty. Note; Base layers of Insulation shall be wedtanlceUy attached using the fastener density listed. Maximum Design The Insulation penis listed are mink, n,sixes and dimensions;if larger panels are used,the Pressure: -45 per;(See General Limitation#7) number of fasteners shall be increased maintaining theism**tenet density.Insulation fasteners shall be tested for withdrawal reelatatace in compliance with Protocol TAB 10$to confirm compliance with the wind load requirements.Please refer to Rooting Application Standard RAS • 117 for insulation.attachment.. GAF requires either a ply of GAFGLAS STRATAVFI eD • }tllminatOr perforated laid dry or a layer of GAFTEMPO PERMALT.CE or wood fiber overlay'• board on all lsocyano rate applications. Top Insulation Layer Insulation Fasteners Fastener GI , (Table 3) Density/ftr Any of the insulation listed for Base Layer,above. .. High Density Wood Fiber,GAFTEMP®High Density Wood Fiber,GAFTEMP Recover Board Mlnirnnm IV thick N/A N/A Pam Mmimnn%"thick N/A N/A i 11s, NM No: 03-0501.02 'a'�, NOA No: 03.0301.02 Expiration Date: 11/0bN8 � Expiratlou Date: 11/06/08 'It.7,1' Approval Date:10/23/03 - 1` Approval Date:10/23/03 'r r Page 13 or 32 %rat,• Page 16 of 32 • Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT _ range and at a rate:of 20-40 lbs/100 ft=. Please refer to Roofing Application Standard RAS 117 for Membrane Type: SBS Insulation attachment.Composite insulation boards used as a top layer shall be Installed with the polylsocyanuratc face down. Deck Type II: Wood,Insulated Base Sheet: Install one ply of GAFGLAS®#75,GAPGLAS i1880 ULTIMA'r`Base Sheet, Deck Description: "/,}or greater plywood or wood plank GAPGLAS®PLY 4®,GAPGLAS Flex Ply""6,GAFGLAS STRATAVENT° Plimioatcr Perforated(laid dry),RUBEROID Modified Base Sheet,RUBEROID System Type C: One or more layers of insulation simultaneously attached;'Buz layer optional. MOP Smooth,RUBEROID®20,RUBEROID SITS lieu-Weld**'Smooth or Ail Genre!and System Limitations shall apply. RUBEROID SBS Heat-Weld 25 directly.over the top layer of insulation. Adhere with any approved mopping asphalt applied within the BVT range and at a rate of Base Insulation Layer Insulation Fasteners Fastener 20-40 lbsJaq; (see General Limitation#4). (Table 3) Density/fta , ACFoanrl,GAFTEMP®Isotherm R.GA TE14iP Isotherm RA,GAFTEMP,Isotherm RN, Ply Sheet: (Optional,required when using RUBEROID 20) One or more plies GAPGLAS B? CA EnergyGuard,EnergyGuard RA PLY 40,GAFOLAS Flex Ply 6 sheet or GAFGLAS#80 ULTIMA adhered in a Mfinitnum 13"thick N/A N/A full mopping of approved asphalt applied within the BVT range and at a rate of 20. ENRGX 2, 40 Ibsfaq. Mlnimarm 1.4"thick N/A N/A . Membrane: One ply of Ruberoid®Torch Smooth,Ruberoid®Teeth Granule,Ruberoid® ISORor,ENRGY 2 Phis,GAFTEMP Composite A,GAFTEMP Composite N,GAFTEMP Torch Plus Granule or RubrmidCD Torch FR torch applied according to Composite,BMCA EnergyGnard Composite,EnergyGuard RA Composite manutaeiut+a's application instroctions. Minimum 1.5"thick N/A N/A Or ' One or more plies of RUBEROIDtb SBS Heat-Weir',PLUS,RUBERODI)®SBS Petite,GAPTEMPP PERMALITE® IIeat-We1dru PLUS FR,RUBEROID®SBS Heat-Weldm 170 FR,RUBEROID® Minimum 34"thick N/A N/A • SBS Heat Weldor,RUBEROID®SBS Hui-Weldor Smooth,RYJBEROII® Fiberglas UltraClad 'SBS and RUBEROID®SBS Heat-Weld"'25 applied according to u manufactures application instructions. Minimum /ns"thick N/A N/A Surfacing; (Optional)Install one of tits following: Wood Fiber,GAFf'EMP®Fiberboard Miaimrun 1"thick N/A N/A • 1. Gravel or slag applied at 400 lbdsq.and 300 IbJaq.respectively in a flood coat Note;AU layers dull be slatnittttseonely fastened;see top layer below for fasteners and density, of approved asphalt at 60 lbfsq. Insulation ponds Hated arts minimum sixes and dimeneionp if larger panels are tweed,the number 2. GAF Premium Pilo:red Aluminum Roof Coating,at 1.3 gal./sq.or GAF •WeatherCoat'Emulsion at 3 gal./sq. (Tor h Smooth applications only) of p icati n Stand daRAS ed11 rmaintaininginsulation the sass fastener density. Please refer to Roofing 3. OAF Weathercote®MB+(Matrix 715 MB Coating),Applied at 1 to 1.5 Application Standard RAS 117 for 6uulatton attae6man6 galiaq. Top Insulation Layer Insulation Fasteners Fattener 4. Top Coat®Surface Seal SB(Manix 602 SB Coating),Applied at 1 to 1.5 (Table 3) Dmatty/ft" gal./sq. ACForrm-I,EuergyGuard RA Miplmrnar 13"thick 1,2,6,9,13 or 14 1:3 fta Maximum Design ENRGY 2,GAFTEMP Isotherm RN Pressure: -45 pusf;($ee General Limitation+ Mminatm 1.4"thick 1.2,6,12,13 or 21 . 1:3 ft= • GAFFEMP®Isotherm R,GAFTEMiP Isotherm RA,BMCA EnorgyGnard et Minimum 1.3"thick 1,2,6,9,13,14,18 or 21 1:3 fta ENRGY 2 Plus,GAFTEMP Composite N,GAFTEMP Composite,GAFTEMP Composite A, BMCA EnergyGuard Composite,EnergyGuard RA Composite Minimum 1.5"thick 6,9,18 or 21 1:3 ftr Perlite,GAFTEMPOI PERMALITE Minimum 54"thick 1,6,9,13 or 21 1:2 ft a'I'6% NOA No:03.0501,03 `,r r a,. - Esplration Dace: 11/06/08 ;, NOA No: 03 0501.02 Expiration Date 11/06J08 fi �wo Approval Da :10I23/03 (''',^�; Approval Date:10/23/03 1 rt Page 17of32 'rrr1`, Page 18 of 32 • Fiberg Minimum Membrane Type: APP/SBS Heat Weld Minimum"V thick 1,2,6,9.1Z 13,14,IS or 1:2,67 ft, 21 Deck Type II: Wood,Insulated Wood Fiber,GAFTEMP®Fiberboard,GAFTEMP liigb Density Fiberboard Minimum 1"thick 1,2;6,13,14 or 21 1:2 ft' Deck Description: �s/�="or greater plywood or wood plank Note:luau atIon pantie listed are minimum aims and dimensions;If larger panels are used,the System Type C: One ar mom layers of imsulatloa simultaneously attached;Base layer optional number of fasteners shall be increased maintaining the same fastener density. Please refer to All General and System Limitations shall apply, Rooting Application Standard RAS 117 for insulation attachment.GAF requires either a ply of GAFGLAS STRATAYENT®Eliminator Perforated laid dry or a layer of GAFTEMP41t Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/tt3 PERMALITE or wood fiber overlay board on all laocrannata applications. ACPoem•1,GAFTEMPO Isotherm R,GAFTEMP Isotherm RA,GAFTEMP,Isotherm RN, , Base Sheet: Install one ply of GAFGIAS®1f75,OAFGTAS#80 Clltin&'Base Sheet BMCA EnergyGuard,EnergyGuard ItA GAPOLAS®PLY 40,OAPGLAS®PLY 6®,GAPOLAS PlexPlyn 640 Minimum 1.3"thick N/A N/A GAFOLASO STRATAVENTO Perforated(laid dry),RUBBROID Modified Base Sheet,RUBBROID MOP Smooth or RUBEROID®20 directly over the top layer E'NRG '2, of insulation. Adhere with any approved mopping asphalt applied within the i3VT Minimum 1.4"thick N/A N/A range and at a rate of 20-401k/sq. If base that it applied directly to 1SORoc,ENRGY 2 Plus,GAFTEMP Composite A,GAFTEMP Composite N,GAFTEMP polyisocyannrate insulatioo only a spot or strip mopped application as detailed in Composite,Multi-Max,BMCA EnergyGuard Composite,EnergyGuard RA Composite this approval the use of an overlay board is approved; Minimum l.5"thick N/A N/A (see General Limitation#4). . Ply Sheet: (Optional)One or more plies GAPOLAS PLY 44),GAFOLAS Flex Ply 6 sheet or Perlite,GAFTEMPO PERMAL ITE®,GAY E MP Recover OAPGLAS#80 Ultima adhered in a full mopping of approved asphalt applies Minimum 14"thick . N/A N/A • within the BYE range and at a rate of 20-40lbafaq. Fiberglas • Membrane: One or more plies of RUBEROIDO 20,RUBBROID 30,RUBBROID 30 PR Minimumsins"thick N/A N/A RUBBROID MOP Smooth,Ruberoid4C Mop 170 PR,Rulxeroide Mop Granule, Wood Firer,GAPTEMPO Fiberboard • RUBEROID MOP PLUS,RUBBROID MOP FR,RUBBROID Dual PR or Minimum 1"thick N/A, WA . RUBBROID ULTRACLAD®,fully adhered in an approved asphalt at an - application rate of 20r10lbeisq. Notes All layers shall be almnitaneoosdy fastened;see top layer below for fasteners and density. Insulation panels listed are minimum sites and dimensions;If larger panels are used,the number Surfacing: (Optional,required if RUBBROID MOP Smooth or RUBBROID 20 is top ' diastases'shall be Mauled maintaining the same fastener density. Please refer to Roofing membrane)Install one of the following: Application Standard RAS ill for sedation attachment. 1. Gavel or slag applied at 400 lbisq.and 300 lb./sq.respectively in a'flood coat Top Insulation Layer Insulation Faafertern Fastener = of approved uphalt at 60 lb/sq. • (Table 3) DeneltyJft 2. GAFOLAS.Mmerai Surfaced Cap Sheet in an approved asphalt at an ACFoanr-L,EoergyGuard RA . application rate of 25 lb/sq.±1546. Minimum 1.3"thick 1,2,6,9,13,14 or 21 1:3 ft: ' 3. GAP Weathercotal4 MB+Matrix 715 MB Coating), Applied at 1 to 1.5 E'NRG'Y 2,GAFTEMP Isotherm RN galisq• Minimum 1.4"thick 1,2,6,9,13,14 or 21 1:3 ft' 4. Top Coati) Surface Seal SB(Matrix 602 SB Coating),Applied at 1 to 1.5 • • gal./sq. GAFTEMP2i Isotherm R;GAFIEMP40 Isotherm R,BMCA EnergyGuard • Mlniruuria 1,3"thick 1,2,6,9,13.14,18 or21 1:3 ft2 b, Maximum Design El1RGY 2 Plus,GAP'TEMP Composite N,BMCA EnergyGuard Composite,EnergyGuard RA Preaaure: •45 pst;(See General Limitation Composite Minimum 1.5"thick 6,9,18 or 21 1:3 ft' Perlite,GA6'TEMPO PERMALTTE Minimum Vs"thick • 1,6,9,13 or 21 1:2 ft' trir�r NOA No: 03 4)501.02 �tt'/' NOA No: 03-0501.02 Expiration Date: 11/06/08 Expiation Date: 11/06/08 1. Approval Date:10/23/03 1':..'7 Approval Date:10/23/03 ,1.4.1.i. :r j�1° Paso 19 of 32 'r, �° Page 20 of 32 Fiberglas Membrane Type: SBS Minimum"/; thick 1.2,6.9.12.13,14,18 or 1:2.67 fts Deck Type 11: Wood,Insulated 21 Wood Fiber,GAFTEMP®Fiberboard,GAFTEMP High Density Fiberboard Deck Description: 19/n"or greater plywood or wood plank Minimum 1"thick 1,2,13,14 or 21 1:2 ft, System Type D(1): Insulation and Base sheet simultaneously attached Note:Insulation panels listed are minimum fazes and dimensions;if larger panels are used,the number of fasteners shall be Increased maintaining the same fastener density. Please refer to A1lteneral and System Limitations shall apply. Rooting Application Standard RAS 117 for insulation attachment. GAF requires tither a ply of One or more layers of any of the following insulations. GAFGLAS STRATAVENT®Eliminator Perforated laid dry or a layer of GAFTEMP® Insulation Layer Insulation Fasteners Fastener PERMALITE or wood fiber overlay board on all tsocyanurate applications. (Table 3) Density/ft? Base Sheet: Install one ply of GAFGLAS®#75,GAPGLAS#80 Ultimarx Base Sheet ACFtwm-1,ENRGY 2,GAFTEMP®Isotherm R,ENRGY 2 Plus,GAFTEMP Isotherm RA,, GAFGLAS®PLY 4®,GAFGLAS FlexPly' 6®,GAFGLAS0 STRATAVENI'® GAFTEMP Isotherm RN,BMCA EnergyGuard,EnergyGuard RA,EnergyGuard RA Composite Eliminator Perforated(laid dry),RUBEROID Modified Base Sheet,RUBEROID BMCA EuergyGuard Composite,GAFTEMP Composite,GAFTEMP Composite A,GAFTEMP MOP Smooth or RUBEROID®20 directly over the top layer of insulation. Composite N loosely laid with firmly butted Joints.Minimum thickness,1.3". GAFTEMP High Adhere with any approved mopping asphalt applied within the EVT range and at a Density Fiberboard,GAFTEMP Fiberboard,minimum thickness 1". rate of 20 40lbsJsq. If base sheet is applied directly to polyisocyanurate Base Sheet; Install one ply of GAMMAS®#75,GAFGLAS#80 Ultima'Base Sheet, insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved;(see General Llmitatlon#4). OAFGLAS®STRATAVENTO iliminator Perforated or RUBEROID®20 base Ply Sheet: (Optional,required when using RUBEROID 20) One or more plies GAFGLAS sheet applied over the loose laid insulation with 2"side laps ma h•nically fastened to deck as described below; PLY 4®,GAFGLAS Flex Ply 6 sheet or GAFGLAS#80 ULTIMA adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- Fastening Options: GAPITTE#12 or#I4 Screws and 3"Plates are installed through the base sheet 40 lbsJsq. and insulation in 3 rows 12"o.c. One row Is in the 2"side lap,The other rows Membrane: One ply of Ruberoid®Torch Smooth,Ruberoid®Torch Granule,Ruberoid® are equally spaced approximately 12"c.c.in the field of the sheet.(Maainium Torch Plus Granule or Ruberoid®Torch FR torch applied according to Design Pressure—4S psf,See General Limitation#7) manufacturer's application instructions. Or. GAPTI'1T?#12 or#14 Scrowa and 3"Plates in 4 rows 12"o.c. One row is in the One or more plies of RUBEROID®SBS Hat-Weldru PLUS,RUBF-RO1D®SBS 2"side lap. The other rows are equally spaced approximately 9"o.c,In the field Hcaf-Weldor PLUS FR.RUBEROID®SBS Hai•We1dns 170 FR,RUBEROID® of the sheet. (Maximum Design Pressure 40 pe,,See General Limitation*7) SBS Heat-Web:I'm,RUBEROID®SBS Heat-WeldTk Smooth,RUBEROID® OAFTTTE#12 or#14 Screws and 3"Plates are installed through the base sheet UltraCladTe SBS and RUBEROID®SBS Heal-WeldnI 25 applied according to and insulation in 4 rows 8"o.c. One row is in the 2"aide lap.The other 3 rows manufacturer's application instructions. aro equally spaced approximately 9"o,c,in the field of the sheet. (Maximum Surfacing: (Optional)Install one of the following: Design Pressure—75 psi,See General Limitation#7) Ply Sheet; (Optional)One or more plies GAFGLAS PLY 4®,GAPOLAS Plea Ply 6 sheet, 1. Gravel or slag applied at 400 lb./sq.and 300 Ibisq.respectively in a flood coat GAFGLAS#80 Ultima,RUBEROID MOP Smooth or RUBEROID 20 adhered in of approved asphalt at 60 lb/sq. a full mopping of approved asphalt applied within the I3VT range and at a rate of • 2. GAP Premium Fibered Aluminum Roof Coating,at 1.5 gal./sq.or GAP 20.40 lbsJsq. WeathetCoata Emulsion at 3 gal/sq. (Torch Smooth applications only) • 3. GAP Weathercot®MB+(Matrix 715 MB Coating),Applied at 1 to 1.5 Membrane: One or more plies of RUBEROID MOP Smooth,Ruberoid®Mop 170 FR, galJsq. Ruberoid®Mop Granule,Ruberoid®Mop Plus Granule,Ruberoid®20, 4. Top Coat®Surface Seal SB(Matrix 602 SB Coating),Applied at 1 to 1.5 Roberold®30 or Ruberoid0 30 PR or Ruberoid®Mop FR or RUBEROID gal./sq. UltraCledT*r SBS in adhered in a full mopping of approved asphalt applied within Maximum Design the EVT range and at a rate of 20-40 lbsJsq. Pressure: -45 psf;(See General Limitation#7) Or, .i t'"f^ NOA No: 03.0501.02 `,t,nt - NOA No: 03-0501.02 rt Expiration Date: 1L06/08 taL ExpinUors Dale: lI/06/08 Approval Date:10/23/03 `=..'tom Approvpl Date:1003/03 •�,111%' Page 21 of 32 ',FS`s Page 22 of 32 • • One or more plies of RUBEROID MOP Smooth,RUBEROID®Mop Granule, RUBEROIDO Mop 170 FR.RUBEROIDO Mop Plus Granule,Ruberoid®20, Membrane Type: APP/SBS Heat Weld RUBEROIDO 30,RUBEROIDO 30 FR or RU13EROlD©Mop FR or RUBEROID UltraCladT'r SBS in RUBEROU)Modified Bitumen Adhesive at an Deck Type 11: Wood,Insulated application rate of 1•2 gal/sq. ,y Surfacing: (Optional,required if RUBEROID MOP Smooth or RUBEROID 20 is topDeck Description: /rr"or greater plywood or wood plank membrane)Install one of the following: System Type D(1): Insulation and Base sheet simultaneously attached I. Gravel or slag applied at 400lblsq.and 300 lb/sq.respectively in a flood coat • All General and System Limitations shall apply. of approved asphalt at 60 Ib./sq, 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an One or more layers of any of the following insulations. application rate of 25 lb./sq.±15%. Insulation Layer Insulation Fasteners Fastener 3. GAF Weethercote®MB+(Matrix 715 MB Coating),Applied at i to 1.5 (Table 3) Density/fti galJsq. ACFoam•I,ENRGY 2,GAFTEMP®Isotherm R,ENRGY 2 Plus,GAFTEMP Isotherm RA, 4. Top Coat®Surface Seal SB(Macrix 602 SE Coating),Applied at 1 to 1.5 EnergyGuard,EnergyGuard RA GAFTEMP Isotherm RN,GAFTEMP Composite,GAFTEMP gal./sq.. Composite A,GAFTEMP Composite N loosely laid with firmly butted joints.Mlttimtuu thickness, 1.3". GAFTEMP High Density Fiberboard,GAFTEMP Fiberboard,minimum thickness 1". Maximum Design • • Pressure: Sec Fastening above Base Sheet: Install one ply of GAPGLAS®#75,GAFGLAS#80 Ultihrarrr Due Sheet, GAPGLAS®STRATAVBTI'T®Eliminator'Perforated or RUBERODDO 20 base sheet applied over the loose laid insulation with 2"side laps mechanically fastened to deck as described below; Fastening Options: GAFI'ITE#12 or#14 Screws and 3"Plates are installed through the base sheet and insulation in 3 rows 12"o.c. One row 1s in the 2"side lap.The other rows am equally spaced approximately 12"o.e.in the field of the sheet.(Maximum Design Pressure--45 psi,See General Ljmitarian#'J) GAFITTE 012 or#14 Screws and 3"Plates in 4 rows 12"o.c. One row is in the 2"side lap.The other rows are equally spaced approximately 9"o.c.in the field . of the sheet. (Maximum Design Pressure—60 prf,See General limitation#7) GAFITTE#12 or#14 Screws and 3"Plates are installed through the base sheet and insulation in 4 rows 8"o.e. One row is in the 2"side lap.The other 3 rows are equally spaced approximately 9"o.e,in the field of the sheet. (Maximum Design Pressure—75 psi,See General limitation)07) Ply Shut: (Optional,required when using RUBEROID 20) One or more plies GAFGLAS PLY 40,GAPGLAS Flex Ply 6 sheet ce GAPGLAS#80 Ultima adhered in a full mopping of approved uphalt applied within the BVT range and at a tale of 20-40 lbs.sq. • Membrane: One ply of Ruberoid®Torch Smooth,Ruberoid®Torch Granule,Ruberoid® '. Tomb Pita Granule or Ruberoid®Torch FR torch applied according to • • manttfuturer'a application instructions, • Or One or more plies of RUBEROID®SBS Heat-Weld''PLUS,RUBEROID®SBS Hcat.WeIdTM PLUS PR.RUBEROID®SBS Hcat•We1da 170 FR,RUBEROID® SBS Heat-Weld*",RUBEROID749 SOS Heat-Weld"Smooth,RUBEROID® UltraCladm SBS and RUBEROID®SBS Heat•Weldn4 25 applied according to manufacturer's application instructions. „ NOA No: 03.0501.02 1 t rt q/i NOA No: 03-0501.02 F Expiration Date: 1 L'06/08 _ t pendor'Date: 11/06/08 Approval Date:10/23/03 Approval Date:10/23/03 •, Page rt r g �r, �o Page 24of32 Surfacing: (Optional)Install one of the following: Membrane Type: SBS/SBS Cold Applied I. Gravel or slag applied at 400 lb/sq.and 300 lb./sq.respectively in a flood coat Deck Type I Wood,Non insulated of approved asphalt at 60 lbJsq. 2. GAP Premium Fibercd Aluminum Roof Coating,at 1.5 gal./sq.or OAF Deck Description: rv/11'or greater plywood or weed plank decks WeatherCoati Fmuldon at 3 gaL/sq. (Torch Smooth applications only) 3. OAP Weathercote®MB+(Matrix 715 MB Coating),Applied at Ito 1.5 gal./sq. System Type E(l): Base sheet oacchattieally fastened to roof deck 4. Top Coat®Surface Seal SB(Mntrix 602 SB Coating),Applied at Ito 1,5 All General and System Limitations shall apply. gal./sq. Base sheet: GAPOLAS#80 Uitima°u Base Sheet,STRATAVENT®Eliminator Perforated Maximum Design Mailable,RUBBROD)Modified Base Sheet,RUBEROID®20,RUBEROID SBS Pressure; See Fastening Above Heat-Weld7}4 Smooth or RUB$ROID SBS Heat-Weld 25 base sheet mechanically fastened to deck as described below; Fastening GAPGLAS®Ply 4®,OAPGLAS Plea Ptyr's 6,GAFGLAS#15 Base Sheet or any Options: of above Base sheets attached to deck with approved annular ring shank nails and tin cape at a fastener spacing of 9"o.c.at the lap staggered and in two rows 12" • o.c.in the field. (Maximum Design Pressure-41 psf,Sae General Linbltation e7) • GAPOLAS®Ply 4®,OAPGLAS Flex Plyn4 6,OAPOLAS#75 Base Sheet or any of above Base sheets attached to deck with Utiil--Tee(GAPTITE)412 or]#14 Screws and 3"Plates,l2"o.c.in 3 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 12"o.c.In the field of the sheet. (Maximum Design Pressure-41 psf,See General Limitation.V7) GAPGLAS Flex Ply°"6,GAFGLAS#75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin Daps at a fastener spacing of 9"c.c.at the 4"lap staggered and in two rows 9"o.c.in the field. (Maximum Design?senate-52.5 psf,See General Limitation 07) GAPOLAS#75 Base Sheet or any of above Base sheen attached to deck with •• Drill-Tee(GAPTfTB)412 or#14 Screws and 3"Plates,I o.c,in 4 rows. One row is in the 2"side lap.The ollser.rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Designs Pressure-60 p;J,See General Limitation#'7) Any of above Base sheets attached to deck approved annular ring shank nails and 3"inverted Drill-Tee(EMPTIES)insulation places at a fastener spacing of 9"o.c. at the 4"lap staggered in two rows 9"in the field. (Maximum Design Pressure- 61)psf,See General Lfmitation;ir7) GAPOLAS#15 Base Sheet or any of above Base sheets attached to deck with Drill-Tee(GAPTITTB)412 or N 14 Screws and 3"Platen,8"o.c.in 4 rows. One row is ha the 2"side lap. The other rows are equally spaced approximately 9"•o,c. in the field of the sheet. (Maximum Design Pressure-75 psf,See General . • Lbrtitation#7) to Ply Sheet: (Optional)One or more plies GAPGLAS PLY 4®,GAPGLAS Flex Ply 6, GAFGLAS#SO,RUBEROID MOP Smooth or RUBEROID 20 sheet adhered in a full mopping of approved asphalt applied within the BVT range and at a rate of 20• _• 401bs.sq. `oat. NOANo: 03-0501.02 .t?°!�• NOA No: 03.0501.02 „g;,5 Expiration bats; 11/06/08 Expiration Date: 11/06/08 —to.... '► � Approval Date:10/23/03 ` Approval Date:10/23/03 • Page 26 of 32 !rs a.% Page 25 of 32 r rpt. C • Membrane: One or more plies of RUBEROID MOP Smooth.Ituberoid0 Map 170 FR, Ruberoid®Mop Granule.Ruberoid®Mop Plus Granule,Ruberoid®20, Membrane Type: APP/SBS Heat Weld Ruberoid®30 or Ruberoid®30 FR or Ruberoid®Mop FR or RUBEROID UltraCladm SBS in adhered in a full mopping of'approved asphalt applied within Deck Type 1: Wood,Non-insulated Ore EVT range and at a rate of 20-40 IhsJsq. Deck Description: rr/ss"or greater plywood or wood plank decks One or more plies of RUBEROID MOP Smooth,RUBEROID®Mop Granule. System Type E(I): Bose sheet mechanically fastened. RUBEROID®Mop 170 FR,RUBEROID©Mop Plus Granule,Ruberoid®20, RUBEROID®30,RUTIEROID®30 FR or RUBEROID®Mop FR or RUBEROD] All General and System Limitations shall apply. UltraCiadT"'SBS in RUBEROID Modified Bitumen Adhesive at an application Base sheet: GAFGLAS ff50 Ultima""t Base Sheet,STRATA VENT®Eliminator Perforated rate of 1-2 galJsq. Nailable,RUBEROID Modified Base Sheet,RUBEROID MOP Smooth, Surfacing: (Optional,required if RUBEROID MOP Smooth or RUBEROID 20 is top RUBEROLD0 20,RUBEROID SBS kleat•Weld'm Smooth or RUBEROID SBS membrane)Install one of the following: Heat-Weld 25 base sheet mechanically fastened to deck as described below; I. Gravel or slag applied at 400 lbJsq.and 300 lb./sq.respectively in a flood coat Fastening Options: GAFGLAS®Ply 4®,GAFGLAS Flex Ply"'6,GAFGLAS#75 Base Sheet or any of approved asphalt at 60 lbJsq. of above Base sheets attached to deck with approved annular ring shank nails and 2. GAFGLAS Mineral Surfaced Cap Sheet In an approved asphalt at an • tin caps at a fastener spacing of 9"o.c.at the lap staggered and in two rows 12,' application rate of 25 lbJsq.t 15%. o.c.to the field, 3. GAF W eathercote®MB+(Matrix 715 MB Coating),Applied at 1 to 1.5 • (Maximum Design Pressure-45 psf,See General Limitation 17) galJsq. GAFGLAS®Ply 4®,GAFGLAS Flex Piyni 6,OAFGLAS#75 Base Sheet or 4. Top Coat®Surface Seal SB(Marrix 602 SB Coating),Applied at 1 to 1.5 any of above Bate sheets attached to deck with Drill•Tec(GAF 1 its)#12 or#14 gal./sq. Screws and 3"Plates,12"o.c.in 3 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 12"o,c.in the field of the sheet. Maximum Design (Maximum Design Pressure-45 psf See General Limitation 17) Pressure: See Fastening above GAFGLAS Plea Piy?*t 6,GAFGLAS#75 Base Sheet or arty of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o,c.in the field. (Main urn Design Pressure-52.5 psi,See General Limitation#7) GAPOLAS KM Base Sheet or any of above Base sleets attached to deck with - 1fill-Tee(GAFTIIE)#12 or#14 Screws and 3"Plates,12"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9" o.c.in the field of the sheet. (Maximum Design Pressure-60 psf,See General Limitation#7) Any of above Base sheets attached to deck approved annular ring shank nails and 3"inverted Drill-Tee(GA1.141 B)insulation plates at a fastener spacing of 9"a.c, at the 4"lap staggered in two rows 9"in the field. (,Maximum Design Pressure-60 psf,See General Llml/atlan d'7) GAFOLAS#75 Base Sheet or nary of above Base sheets attached to dock with Drill•Tee(GAFIITE)#12 or#14 Screws and 3"Plates,8"o,c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9" o,c.in the field of the sheet. (ilfarimumDesign Pressure-75 psi,See General Limitation#7) Ply Sheet: (Optional except over RUBEROID Modified Base Sheet,RUBEROID MOP Smooth,RUBEROID®20,RUBEROID SBS Hcac.WeldTM Smooth or RUBEROID SBS Heat-Weld) One or more plies GAFOLAS PLY 4®, GAFGLAS®PLY 6®Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rule of 20-40 ibsisq.or Ruberoid Torch Smooth torch applied according to manufacturer's application instructions. NOA No: 03.0501.02 Alf*ram _ NOA No: 03-0501.02 Expiration Date: 11f06/08 � El-Oration Dale: I U06/08 Approval Date:10r23/031.";.'.91" !trrJ Page 27 of 32 %rr7Mo Approval Page 28 of 32 • • Membrane: One ply of Ruberoid®Torch Smooth,Ruberoid09 Torch Granule,Rube:oid® Torch Plus Granule or Ruberold®Torch FR torch applied according to Membrane Type: SBS manufacturer's application instructions. Or Deck Type I: Wood,Non-insulated One or more plies of RUBEROID®SBS Hcat•Weldt'PLUS,RUBEROID® ,9 SBS Heat-WeldTM ID PLUS FR,RUBBRO ®SBS Heat-Weld'M 170 FR, Deck Description: /32"or greater plywood or wood plank RUBEROM®SBS Heat-WeldTM,RUBEROID®SOS Heat•Weldfl Smooth, RUBERO1DQb U1traClacV'SBS and RUBEROID®SBS Heat-Weld,"2S applied System Type E•2: RUBEROED(D 131e Underlaymeat,Base Sheet meth nically attached. according to manufacturer's application instructions., All General and System Limitations&hall apply. • Surfacing; (Optional)Install one of the following: Anchor sheet: OAFGLAS®t180 Ultima'na Base Sheet,RUBEROID®20 base sheet or Tile-Mate Modified Base Sheet applied with a minimum 2"side lap and a minimum 6"end 1. Gravel or slag applied at 400 lb./sq.and 300 Ibisq.respectively in a flood coat lap.Base sheet may be applied at a right angle(90°)to the slope of the deck with of approved asphalt at 601blsq, approved annular ring shank nails and tin caps at a fastener spacing of 6"o.c.at the 2. OAP Premium Fibered Aluminum Roof Coating,at 1.5 gal./sq.or GAP 2"side lap,and two 12'o.c.staggered rows along the center of the sheet. WeatherCose Emulsion at 3 gaUsq. (Torch Smooth applications only) 3. GAP Weathercote®MB+(Mattix 715 MB Outing),Applied at 1 to 1.5 Ply Sheet: (Optional)One,oc more plies OAPGLAS PLY 4®Ply,GAFOLAS PlexPly"6 gal./sq. sheet,GAPGLAS N80 Uhlman',RUBERQID MOP Smooth of RUBEROID®20 4. Top Coat®Surface Seal SB(Matrix 602 SB Coating),Applied at 1 to 1.5 adhered in a full mopping of approved asphalt applied within the EVT range and at gaL/sq. a rate of 20-40 lbsfsq. Maximum Design Membrane: One ply RUBEROIT®MOP,RUBEROID®MOP PLUS,RUBPROIDO SOS Pressure: See Fastening Above Heat-Wetdn'Granule,RUBEROID®SOS Heat V/eldn'PLUS.Tile-Mate Modified Cap or Tile-Mate Modified Cap Plus,membrane may be applied at a right angle(90)to the slope of the dock*adhered in a full mopping of Type IV asphalt applied within the EVT range and at a rata of 20.40 Ibslsq. Membrane shall be balm/tiled to deck with approved annular ring shank nails and tin caps In accordance to applicable Building Code,No palls or tin caps shall be exposed "Membrane may also be installed parallel to the slope of the roof(I.e.strapping). If membrane is strapped,then anchor sheet and ply sheet must also be strapped. Maximum Design Pressure: • Refer to the manufacturer's NOA. Maximum Slope: Must Comply with Roofurg.Appl cation Standard RAS 118,RAS 119,RAS 120 and applicable Building Code. • • _ �.r NOA No: 03-0501.02 `Art,,� • NOA No: 03-0501.02 Expiration Date: 11/06/08 Expiration Date: 11/06/08 Approval Date:l 0/23/03 • naR• 1 Approval Date:10f23/03 , +r,11?; Page 29 of 32 4," !� Page 30 of 32 Membrane Type: SBS Cold Applied for mechanically fastened rile systems only. WOOD DECE.SYSTEM LIMITATIONS: Deck Type 1: Wood,Non-insulated 1 A slip sheet is required with Ply 4 and Flex Ply nt 6 when used as a mechanically fastened base or anchor sheet. Deck Description: o'/ 'or greater plywood or wood plank 2. Minimum/"Dens Deck or'h Type X gypsum board is acceptable to be installed directly over the ss wood dock. System Type E•3: RUBEROID®Tile Undcrlayment"Base Sheet mechanically attached. • GENERAL LIMITATIONS: • All General and System Limitations shall apply. 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Anchor sheet: OAPGLAS®GAFGLAS#80 Ultima 'Base Sheet,RUBPROID®20 base sheet Directory for fire ratings of this product. or Tile-Mate Modified Base Sheet applied with a minimum 2"side lap and a 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with minimum 6"end lap.Base sheet may be applied at a right angle(901 to the slope Product Control Approval guidelines. All other layers shall be adhered in a full mopping of • of the deck with approved annular ring shank nails and tin caps at a fastener •approves asphalt applied within the EYf range and at a rate of 20-40 lbs/sq.,or mechanically spacing of 6"o.a at the 2"side lap,and two 12"o.c.staggered rows along the attached using the fastening pattern of the top layer center of the sheet. 3. All standard panel sizes are acceptable for mechanical attaclunent. When applied in approved asphalt,panel size shall be 4'x 4'maximum. Membrane: One ply RUBEROID®MOP,RUBEROID®MOP PLUS,Tile-Mate Modified . 4. An oveday and/or recovery board insulation panel is required on all applications over closed•ceU Cap or Tile-Mate Modified Cap Plus,membrane may be applied at a tight angle foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet (90')to the slope of the deck*adhered with Ruberoid Adhesive or Matrix Select shall be applied using spot mopping with approved asphalt,12"dram ter circles,24"o.c.;or snip 102 at a rate of 1-2 galsq. Membrane shall be backnalled to deck with approved cropped 8"ribbons in three rows,one at each sidelap and one down the center of the sheet allowing annular ring shank nails and tin caps at a maximum fastener spacing of 6"o.c. No a cootiauous area of ventilation. Encircling of the strips is not acceptable. A 6'break shall be nails or tin•caps shall be exposed, Allow 72 hour cure atior t4 load boa and placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall Installing tiler. be at a ntinimtun rate of 12 Ibs.sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 pet, Y Membrane may also be installed parallel to the slope of the roof(i.e.strapping). 5. Fastens spacing for insulation attachment is based on a Minimum Characteristic Face(F)value of If membrane is strapped,then anchor sheet and ply sheet must also be strapped. 275 Ibf.as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as l ieldtested,are below 275 Ibf.insulation attachment shall not be acceptable. Maximum Design 6. Fastenet spacing for mu•h"nu•a1 attachment of anchor/base sheet or membrane attachment is based • Pressure: Refer to tile manufacturer's NOA, on a minimum fastener resistance value in conjunction with the maximum design value listed within • Maximum Slope: Must Comply with Roofing Application Standard RAS 118,RAS 119,MS 120 a specific system. Should the fastener resistance be less than that required,as determined by the and applicable Building Code. Bulidini Official,a revised fastener spacing,prepared,signed and scaled by a Florida Registered Engineer,Architect,or Registered Roof Consultant may bo submined, Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 1[7. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compilmce with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable,) 8. All attachment and sizing of perimeter nailer:,metal profile,and/or flashing termination designs • shall caform with Roofing Application Standard RAS 111 and applicable wind load requirements.' 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i,e.perimeters,extended corners and corners). (When this limitation is speclflcally referred within this NOA,General Limitation#7 will not be applcable.) 10, All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Nile 9B-72 of the Florida Administrative Code. • END OF THIS ACCEPTANCE Carol„ NOA No: 03•C601.02 ,,tttn, NOA No:03.0501,02 Expiration Date: Ill06108 Expiration Date: 11/06/08 1 " y., Approval Pate:10/23/03 ^� Approval Date:10/23/03 i pP Page 31 of 32 ¢,i`1%* Page 32 of 32