Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
21-0526.02
MIAMI-U^^C^ MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami. Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NQA) www.miamitJade.cov/buildina E,S, Windows, LLC 3550 NW 49'" Street Miami, FL 33142 Scope: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dado County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Tliis NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami-Dade County) and/ or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. Description: Series "EL-100" Aluminum Single Hung Window - L.M.I. Approval document: Drawing No. W16-57, titled "ES-ELIOO Alum Single Hung Wdw. (L.M.I)", sheets 1, 1.1, 1.2 and 2 through 10 of 10, dated 07/13/16, with revision C dated 06/22/20, prepared by Al- Farooq Corporation, signed and sealed by Jalal Farooq, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. Missile Impact Rating: Large and Small MlssUe impact Resistant Labeling: Each unit shall bear a permanent label with the manufacturer's name or logo, Barranquilla, Colombia, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. Renewal of this NOA shall be eonsidered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. Termination of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other puiposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 17-1114.07 and consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. rMIAMI-DADE COUNTY] \mm\\ NOA No. 21-0526.02 Expiration Date: May 04, 2027 Approval Date: October 14, 2021 10/6/21 Pagcl E.S. Windows. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No, 16-0510.22) 2. Drawing No. WI6-57, titled "ES-ELIOO Alum Single Hung Wdw. (L.M.I)", sheets 1 through 10 of 10, dated 07/13/16, with revision B dated 09/26/17, prepared by Al- Farooq Coiporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 17-1114.07) B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of aluminum single hung window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-17-018, dated 03/31/17, signed and sealed by Constantin Bortes, P.E. (Submitted under NOA No. 16-0510.22) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, Test per FBC 2411 3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window, prepared by Architectural Testing, Inc., Test Reports No. F9S04.01-450-18, dated 04/06/17 and revised on 04/25/17, signed and sealed by Justin P. McDonald, P.F. (Submitted under NOA No. 16-0510.22) Manuel Perez, P.E. Product Control ExapnTTer NOA No. 21-fll526.0^ Expiration Date: May 04^2927 Approval Date: October 14,2021 E-1 E.S. Windows. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5*^ Edition (2014), dated 04/12/17 and revised on 04/21/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 16-0510.22) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 12/28/17, expiring on 07/04/23. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance to FBC 5^** Edition (2014) and FBC 6'*' Edition (2017), dated 09/25/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 17-1114.07) G. OTHERS 1. Notice of Acceptance No. 16-0510.22, issued to ES Windows, LLC, for their Scries "EL-100" Aluminum Single Hung Window - L.M.I., approved on 05/04/17 and expiring on 05/04/22. Manuel Pwez, P.l Product Control Exai NOA No. 21-( Expiration Date: May 04)'40l7 Approval Date: October 14,2021 E-2 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W16-57, titled "ES-ELIOO Alum Single Hung Wdw. (L.M.I)", sheets 1, 1.1, 1.2 and 2 through 10 of 10, dated 07/13/16, with revision C dated 06/22/20, prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a Series ES-EL 100 aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-t2413, dated 12/16/20, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5'^ Edition (2014) dated 04/12/17, revised on 04/21/17 and updated on 04/26/21 to comply with FBC 7^'' Edition (2020), prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resoiu'ces (RER) Manuel Perez. Product Control Exaj NOANo. 21-t Expiration Date: May 04^ Approval Date: October 14,2021 E-3 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (continued) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 20-0915.22 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 11/19/20, expiring on 07/08/24. 2. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® Xtra^^' (SGX"') Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 3. Notice of Acceptance No. 20-0622.03 issued to Eastman Chemical Company (MA) for their "Saflex Storm - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 08/06/20, expiring on 12/11/23. 4. Notice of Acceptance No. 21-0216.01 issued to Eastman Chemical Company (MA) for their "Saflex PVB Interlayers - Clear and Colored for Glass" dated 04/29/21, expiring on 05/21/26. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 7"" Edition (2020), and of no financial interest, dated April 27, 2021, issued by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1114.07, issued to ES Windows, LLC, for their Series "EL-100" Aluminum Single Hung Window - L.M.I., approved on 01/18/18 and expiring on 05/04/22. Manud P^ez, P.E? Product Control Exaj NOA No. 21-( Expiration Dale: May 04> Approval Date: October 14,2021 E-4 1/8" HEAT STREN'O. GLASS.090" mterioyerTfosllol PVBBy 'Kuroray Americo. Inc.'OR.090" InlerioyerSentryClosBy 'Kuraroy Amefico, Inc.*OR.090* kiteHoyerScflex Cleor And Color GlossBy 'Eostmon Chflmicol Co.'OR,075" jnlsrioyerSollei CP With PET Core'Eoslmon Chemical Co.'.-•i/e' heat stren'd. glassSILICONEDOWSIL 795DOWSIL 983OOWSIL 2400(HOT MELT)AT 1/4 POINTS OH JTESWDER THAN 36" ONLYr.lASS TYPE '1'5/16" OVEFTALL LAM. CLASS-1/8" TEMP. CLASSAT 1/4 POINTSAa SIZES-3/8" AIR SPACE-1/B" HEAT STREN'O. CLASS.090" IntertayerTroslfol PVBBy 'Kuroray Americo. Inc.'OR.090" IntertayerSentryClosBy 'Kuroray Americo, Inc.'OR.090' InlerioyerSarie« Clear And Color CloseBy 'Eoslmcn Chemicol Co.'OR.075' InterloyerSo(le« CP With PET CoreBy 'Eostmon Cherr^icol Co.'HEAT STREN'D. GLASS1/8" HEAT STREN'D. CLASS.090* InterloyerTrosifol PVBBy 'Kuroray America. Inc.'OR.090" InterloyerSentry^osBy 'Kuroroy America. Inc.'OR090' InterloyerSoflex Clear And Color ClossBy 'Eostmon Chemicol Co.'OR.075* InterloyerSoliex CP With PET CoreBy 'Eostmon Chemicol Co,'1/4" HEAT STREN'D. GLASSSlUCONEDOWSIL 795DOWSIL 983DOWSIL 2400(HOT MELT)AT 1/4 POINTS ON LITESWIDER THAN 36* ONLYCLASS TYPE -2'7/16" OVERALL LAM. CLASS-1/8" TEMP. GIASSSlUCONEDOWSIL 795OOWSIL 983DOWSIL 2400(HOT MELT)AIR SPACE-1/8" HEAT STREN'D. GLASS.090' IntertayerTrosilol PVBBy 'Kurcr<9 America. Inc.'OR,090" interloyerSentryClasBy 'Kuroray America, inc.',090" InterloyerSoliex Clear And Color GlossBy 'Eostmon Chemicol Co.'OR.075" InterloyerSollex CP With PET CoreBy 'Eostmon Chemical Co.'1/4" HEAT STREN'D. GLASSSlUCONEDOWSIL 795DOWSIL 983DOWSIL 2400(HOT MELT)GLASS TYPE 'li'7/8" OVERAli IHSUL LAM. CLASSAT 1/4 POINTSALL SIZESGLASS TYPE 'gi'7/8' OVERALI INSUL. LAM. CLASSSPACFR:"HEUMA' LOW PRORLE ALUMINUM SPACERBY 'LINGERMANN GMBH'AROUND THE PERIMETER OF THE GLASS.PERIMETER SEALANT:SlUCONEOOWSIL 791GE 2000ES-ELIOOALUMINUM SINGLE HUNG fflNDQWSEE SHEETS 2 AND 3 FOR DESIGN LOAD CAPACITY.APPROVAL APPUES TO SINGLE UNITS OR SIDE BY SIDECOMBINATIONS OF S.H./S.H. OR SINGLE HUNG WITH OTHERWINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USINGMIAMI-DADE COUNTY APPROVED MULUONS IN BETWEEN.LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVALWILL APPLY TO ENTIRE SYSTEM.THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THEREQUIREMENTS OF 'mE 2020 (7TH EDITION) FLORIDA BUILDING CODEINCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).IBY OR 2BY WOOD BUCKS & BUCK FASTENERS BY CITHERS. MUST BEDESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADSTO THE BUILDING STRUCTURE.ANCHORS SHALL BE CORROSION RESISTANT. SPACED AS SHOWN ON DETAILSAND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASEMATERIAL SHALL BE BEYOND WAU. DRESSING OR STUCCO.A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.ALL SHIMS TO BE HIGH IMPACT, NON-METAUJC AND NON-COMPRESSIBLE.MATERIALS INCLUDING BUT NOT UMITED TO STEEL/METAL SCREWS, THATCOME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THEREQUIREMENTS OF THE 2020 FLORIDA BLOG. CODE & ADOPTED STANDARDS.THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATIONFOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACYOF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FORWATER INFILTRATION RESISTANCE ETC.CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY.AND TO BE REVIEWED BY BUILDING OFFICIAL.DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASD)'.[ THESE WINDOWS ARE RATED FOR LARGE <Sc SMALL MISSILE IMPAC1 SHUTTERS ARE NOT REQUIRED.PRODUCT APPROVEDae complying with the FloridaBulldlitg CodeMOA-No. 21-0526.02Approval Date:Bw; t'JClillie: OuK.5/04/2027MiamtDada PreductXantrolMAY 2 0 2021O ^ <0ZsjSo ^drawing no.W16-57(sheet ^ of 10] t/2" MIN. TYP.1/2* MIN. TYPGLASS BITEO O W) Q > gSf5'tfg9.2oIIIXs5SILICOENOOWSIL79Iw■S "" 1v>9CLASS1 "ZpUi8GLASSGLASS BITE1/2 MIN. TYPEXTERIORGLASS BITE1/2* MIN. TYP,GLASS BFTET/2* MIN, TYP.CLASS BITEMf. 07-n-i» )(reviS'0ns■*11101 dolev>yS -i-.^ t2'!oen 3O•sj 9•caN: 1/2- . ri'. by; TARIQ|chk, by:descflDtionCEMERN. REVISIONES-EL100 ALUM SINGLE HUNG WOW. (L.M.I.)E.S. WINDOWS. LLC3550 N.W, 49 STRECTMIAMI, FL, 33142TEL, (305) 638-5151 FAX, (305) 638-5158AL-FAROOQ CORPORATIONENGINEERS & PRODUCT DEVELOPMENT9360 SUNSET DRIVE. SUITE 220MIAMI. FLORIDA 33173 (C.A.N. 3S3B)TEL. (306) ae4-aiOO FAX. (906) 362-6978fc 1/2 M(N. TYP,GLASS ant5 dZ BU 49 E!! X0 la-S car. by. tariocbk. by1/2" MIN. TYP.GLASS enr(S(?)ogr?> oc ^5 TJ-n <O3) OV) T3l(re7ision5hodot®dpscnotiohcDfi.22.20CENTRAL RCVlStON.ES-EL100 ALUM SINGLE HUNG WOW. (L.M.I.;E.S. WINDOWS. LLC3550 N.W. 49 STREETMIAMI. FL- 33142TEL. {305) B38-6151 FAX. (305> S38-5158AL-FAROOQ CORPORATIONENGINEERS & PRODUCT DEVELOPMEOT9360 SUNSET DRIVE. SUITE 220MIAMI, FLORIDA 33173 (Cji.N. 3S3B)TEL (305) 2e4«10O FAX. (305) 262-6S7BfcC0MP-ANL\W16-57ES O > CD O Z^ m (/) n> -nO W -•?oo O322:5§(/) OJ? =-H ^ ^ m> p ^ c/1rn 5 —• oS ^ w y3«8;o I Xo920 (/] 0^ X1 s w □F1 ^ P >9 51 o mM C— 10SS35X 5PPGio *a ^I il-:^S w s » Mm d S .3O1 + £•-a COo ob bTJ TJ10 toM dC1r 'uI +-si -sio ob brsso9 «'eE —'f5 .toE M CO<0COOa 91o ob b35 35*n^ 5 n^lls:P s^32 WS 1iio bb b"O TJto COC? 9WINDOW HEIGHT38 1/SVENT HEIGHT(STD. sia]37 3/<VENT HEIGHTChi-RISE SIU-134 U2'D.L.O. (VENT](HI-RISE SILL]34 1/4'34 1/4D.L.O. (nx. LITE]O.L.O. (VENT](STO. SILL)JAMBSJAMBCORNOIS> 36' MAX.JAMBCORNERSWINDOW HEIGHT©- - 4^4.- -0J L12"MAX.WINDOW HEIGHT:>\\ iJAMBSJAMBCORNERSO)Ior-sjJsW: BT-13-18no oote I Pv description"««'•; i/2"-f-0'NO CHNHOC TMS SHECTNO CHAHCC TMS SXC^SCXtAAL RCWSCMES-EL100 ALUM SINGLE HUNG WDW. (LM.I.)E.S. WINDOWS. LLC3550 N.W. 49 STRECTMIAMI. FL 33142TEL (305) 63S-5151 FAX. (305) 63B-51S9AL-FAROOQ CORPORATION {EISfCINEERS & PRODUCT DEVELOPMENT r9360 SUNSET DRIVE, SUITE 220 !MIAMI. FLORIDA 333.73 fC.A.M 353«; iTEL (3081 204-8100 FAX. (30g> 202-6978 |fcCOMP-ANL\W1B-S7ES 53 1/8"53 1/e53 1/8WINDOW WIDTHWINDOW WIDTHWINDOW WIDTH¨7 1/2D.LO. (FIX. UTCJFALSE UUNT1NS(SURFACE APPUED)UAY BE USEDHEAD6* UAX21" MAXHEAD/SILL21 MAX.HEADCORNOGHEADCORNERSHEAD47 1/2D.L.O- (VENT5SO 1/850 1/a50 1/8VENT WIDTHVENT WIDTHVENT WIDTHTYPICAL ELEVATIONUNEQUAL LfTES (ORIEL TYPE)FLANGE FRAMESTYPICAI FLEVATIONUNEQUAL LfTES (ORIEL TYPE)FLANGE FRAMES WITH FLUSH AOAPIIRTYPICAL ELEVATIONUNEQUAL LfTES (ORIEL TYPE)FLANGE FRAMES WITH FIN ADAPTERGUSS TYPES:"r, '2'. "li', '2i'. 'SA", "aAi', "Q", "Ai"MAXIMUM DESIGN LOAD RATING = + 60.0 PSF(TOR SIZES SHOWN ABOVE OR SMAaER) — 00.0 PSFSTD. FRAME SILLGUSS TYPES:r'l". '2'. 'H', '2i". "SA", "ZAi*. '3'. '4i'MAXIMUM DESIGN LOAD RATING = + 80.0 PSF(FOR saES SHOWN ABOVE OR SMALLER) — 80.0 PSFHI-RISE FRAME SILLFOR ALTERNATE SIZE UNITS MAX. FRAME AREA OF VflNDOWNOT TO EXCEED TESTED FRAME AREA OF 28.04 SO. FT. OR 53-1/8" WIDTH.PRODUCT APPROVED•s complying with tho FloridaBuOdlng CodaWOA-Mo. 21.0526.02Approval Daia; 05/04/2027By:NOTE:GUSS CAPACITIES ON THIS SHEET AREBASED ON ASTM El 300-09 (3 SEC. GUSTS)AND FLORIDA BUILDING COMMISSIONDECURATORY STATEMENT DCA05-0EC-219Mlam,^Dsda Produc,tX^trelMAY 2 0 2021% %o•>i)drowing no-W16-57[sheet 3 of 10] TYPICAL AMCHORSSEE ELEV.FOR SPACir<GWOOD BUCKMETALSTRUCTUREESCE OlST.EDCE OlSTTYPICAL ANCHORS \SEE ELEV.-JFOR SPACINGTYPICAL ANCHORSSEE ELEVFOR SPACINGWF.EPHOLES:W1 = 1-J/8" X 1/4" WEEPHOLES AT 4' FROM EACH ENDOPTONAL TO»>RINC LATCHWOOD BUCKI MIAMI-DAOE COUNTY APPROVED II I MULUON & MULLION ANCHORS |SEC SEPARATE NOA !EDCE DISTTYPICAL ANCHORSSEE £L£V.FOR SPACINGWOOD BUCKS AND MCTAL STRUCTURE NOT BY 'E.S. WINDOWS'MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEMAND TRANSFER THEM TO THE BUILDING STRUCTURE.TYPICAL ANCHORS: see elev. for spacing1/4- DIA. ULTRACON+ BY 'DEWALr (Fu=T64 KSi. Fy=l« KSl)INTO 2BY WOOD BUCKS OR WOOD STRUCTURES1-1/2" MIN. PENETRATION INTO WOOD (HEAD/JAMBS)THRU 10Y BUCKS INTO CONC, OR BLOCKS1-1/4" MIN. EMBED INTO CONCRETE (HEAD/JAMBS)1-1/4* MIN. EMBED INTO BLOCKS (JAMBS)DIRECTLY INTO CONCRETE OR BLOCKS1-1/4" MIN. EMBED INTO CONCRETE (HEAD/JAMBS)1-1/4* MIN. EMBED INTO BLOCKS (JAMBS)1/4' DIA. TEKS OR SELF DRILLING SCREWS (GRADE S CRS)INTO MIAMI-DADE COUNTY APPROVED MULUONSORINTO METAL STRUCTURES (HEAO/JAMBS)(3) THREADS MIN. PENCTRATION BEYOND SUBSTRATEALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.)STEEL; 1/8" THK. MIN. (Fy = 36 KSI MIN.)(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)TYPICAL EDGE DISTANCEINTO CONCRETE AND MASONRY = 2-1/2" MIN.INTO WOOD STRUCTURE = 1" MIN.INTO METAL STRUCTURE = 3/4" MIN.WOOD AT HEAD. SILL OR JAMBS SC - 0.65 MIN.CONCRETE AT HEAD, SILL OR JAMBS f'c - 3000 PSI MM.C-90 HOLLOW/FILLED BLOCK AT JAMBS fm - 2000 PSI MIN.PRODUCT APPROVEDas cemp^ii^ with the FlorfclaBuDdIng iNOA-Ne.21-0526.02Ap^val Pate; 0ST04/202TMtami^ade ProducfCe/itralWAV 2 0 2021'/ijiiuiy(Qz< ^0 d a sft. a 2 iK og s0S5|2V A (j He 8< W 3 L. rf?H-iSic4 ui o> E Prdrawing no.W16-57[sheet 4 oT 10] EDGEDlSr-i3-ia Urevigions:no< dote" by deschtnionfCOi«: 1/2* • 1dr. by: TAfllOehk. by02BY WOOD BUWOODCTDREuES-ELIOO ALUM SINGLE HUNG WDW. (L.M,!,)E.S, WINDOWS. LLC3550 N.W. 49 STREETMIAMI, FL 33142TEL. OOS) 698-5151 TAX. (90S) 698-5156AL-FAROOQ CORPORATIONENGINEERS & PRODUCT DEVELOPMENT9360 SUNSET DRIVE. SUITE 220MIAMI. FLORIDA 33173 (Cjt.lf. 353B)TEL (3061 aa*S100 FAX. (3061 262.^076fcCOMP-ANL\WI6-S7ES 1/4- »UX.WINDOW HDGKTEXTERIOR1/4* MAX,1/4" MAX3»3;rHr"«f-odMOM•g■|8ft*o =■Fo.p0>3(nrevisjons:07-13-16aescfiotionBeol«: i/2' - 16y: 7ARI0BCNnu RCVtSONehi^ by;ES-EL100 ALUM SINGLE HUNG WDW, (LM.I.}E.S. WINDOWS. LLC3550 N.W. 49 STREETMIAMI, FL, 33U2TtL (305) 638-5151 FAX, (305) 638-5168AL-FAROOQ CORPORATIONENGINEERS & PRODUCT DEVELOPMENT9360 SUNSET DRIVE. SUrTE 220MIAMI. FLORIDA 33173 (C.*.N. 3S38)TEL.O0B)3eA«ll>0 FAX, (30S1 2e3.«97BfcC0MP-ANL\W16-57ES] ILLUSTRATIVE DTLS. ONLYTYPICAL ANCHORS-SEE ELEV., FOR SPACINGOR INT. FINISHESBY E.S. WDW.1zf nvx■.»/nl , —L-!-• 4TYPICAL ANCHORS: SEE ELEV. FOR spacingwnnn snREws (grade 2 crs)INTO 2BY WOOD BUCKS OR WOOD STRUCTURES1-1/2' MIN. PENETRATION INTO WOODflO lEKS/SELF DRILLING SCREWSAT 6 FROM ENDSAND 12 O.C. WAX.1/«- MAX,|10 TWS/SELF DRILLING SCREWSAT 6 FROM ENDSAND 12 O.C. MAX.TYPICAL ANCHORSSEE ELEV.—'FOR SPACING1/2* MINWSTAT.IAT10N nRTAll-S fflTTl FIN FRAME ADAPTERSEE SHEETS 4 4 S FOR WINDOW DETAILSTYPICAL ANCHORS-SEE ELEV.FOR S>ACINSPRODUCT APPROVEDptying with the Floridaa CodeBuildingNOA-No.21-0526.02flORl/ I t 111 I 1drflwing no.W16-57[sheet 7 olTo)#10 TEKS/SELF DRILLING SCREWSAT 6 FROM ENDSAND 12 O.C. MAX.EXTERIORWINDOW WIDTHApproval Date; 05/04/2027B«T l''klsiuc^.MlamE-Oad. ProduetXontrol 3>iII— J I5 "z ng ^0 S." arsgoZ 33 o? ®' cH;I'3-aH <1 |sN nL2; ,<trr«ii'n<:r o Q\^Q-O) 3'01"nJdote 07-1}-1Etealt: 1/2* n 1*ByrSescfiplTdhRfV. ACR couuonsMO CHANCC TMIS SMEHeCNCRAL RCV^OMES-ELIOO ALUM SINGLE HUNG WDW. (LM.I.)E.S. WINDOWS. LLCJ550 N.W. 49 STREETMIAMI. EL 35142TIL. (305) 635-5151 EAX. (305) 638-51S8AL-FAROOQ CORPORATIONENQINEERS & PRODUCT DEVELOPMENT93B0 SUNSET DRIVE. SUrTE 320MIAMI. FLORIDA 33173 (Cjk.N. 3S38)TEL (306) 264-8100 FAX 1306) 263-6976fcC0MP-ANL\W16-57ESl ^1.295—I-2.e572.9172.BI72.7B0— .062£'2) fiUSH FRAME ADAPTER1.1S7—1.107© FRAME HEAD2.812— .0831.500-1.187 —FRAME JAMB3.142.0491.3742,780© FLUSH FRAME ADAPTER WITH FIN2.814— 1.407E8) FIX. MEETING RAJL078-".050 .974050 .9742.917.474@ FRAME Sia (STANDARD)1.3133.1411.93S062 —2.6863.1841.014E5) VENT TOP RAIL2.347E3_) FRAME SILL (HI-RISE)2.1481.187 —E6) VENT BOTTOM RAILEl3i HEAD SCREW COVER— .062 1.2601.1871.4211.078 —— .078.683(p) VENT SIDE RAIL^ SPRING LOADED LATCHEl4l JAMB SCREW COVER.519,050—.974I_L062 .974L,GLA2ING BEADSPRODUCT APPROVEDas complying with the Florida ,^1Building CodeNOA-No. 21-0526.02Approval Date! Q5/04/2027Miam^Dade PraductXoktral7 ^ Dis HM A T a: ® o oii 0. O u Sj Q8=^-5W Q S8. O a o S "laggs Ii<SSs i::No.may 2 0= [°Sdrawing no.W16-57(sheet 9 of lOj 'nullrifaal«: P7-H-IS llrevisions3 " 'fno rtn?P^ <1. JOnol OoteO)*11^1 i/r - r ]I by I descriptionNC CHMGC THIS SHCr° 01 3^ win'vj P(dr. b)rt 7AR1Q \] c 09.27 2CNO CKMCC THIS SNCCTCCNCRAL ftCVlSiONjfek fty:ES-EL100 ALUM SINGLE HUNG WDW. (L.M.I.)E.S. WINDOWS. LLC3550 N.W. 49 STREETMIAMI, FL. 33142TEL (505) 658-5151 FAX. (505) 658-5158AL-FAROOQ CORPORATIONENGINEERS & PRODUCT DEVELOPMENT9360 SUNSET DRIVE. SUITE 220MIAMI. FLORIDA 33173 (C.A.y. 31138)TEL (306) 364-6100 FAX. (3061 3634078cCOMP-ANLWVie-57ES]